Abstract
BACKGROUND:
Field-based walk tests conducted remotely may provide an alternative method to a facility-based assessment of exercise capacity for people with advanced lung disease. This prospective study evaluated the level of agreement in the distance walked between a 6-min walk test (6MWT) and an incremental shuttle walk test performed by using standard in-person procedures and test variations and settings.
METHODS:
Adults with advanced lung disease underwent 4 study visits: (i) one in-person standard 6MWT (30-m corridor) and one in-person treadmill 6MWT, (ii) a remote 6MWT in a home setting (10-m corridor), (iii) 2 in-person standard incremental shuttle walk tests (10-m corridor), and (iv) a remote incremental shuttle walk test in a home setting (10-m corridor). A medical-grade oximeter measured heart rate and oxygen saturation before, during, and for 2 min after the tests.
RESULTS:
Twenty-eight participants were included (23 men [82%]; 64 (57–67) y old; 19 with interstitial lung disease [68%] and 9 with COPD [32%]; and 26 used supplemental oxygen (93%) [exertional
CONCLUSIONS:
Differences in the distance walked may have resulted from different track lengths, widths, and walking surfaces. This should be considered in test interpretation if tests are repeated under different conditions.