Bone anchorage is a promising new field in orthodontics and already a wide variety of bone anchorage devices (BADs) are available commercially. This review aims to assist clinicians by outlining the principles of bone anchorage and the salient features of the available systems, especially those that may influence the choice of a specific BAD for anchorage reinforcement.
KanomiRMini-implant for orthodontic anchorage. J Clin Orthod1997; 31: 763–67.
2.
KyungHM, ParkHS, BaeSM, SungJH, KimIBDevelopment of orthodontic micro-implants for intraoral anchorage. J Clin Orthod2003; 37: 321–28.
3.
ParkHS, KwonOW, SungJHMicro-implant anchorage for forced eruption of impacted canines. J Clin Orthod2004; 38: 297–302.
4.
DalstraM, CattaneoPM, MelsenBLoad transfer of miniscrews for orthodontic anchorage. Orthodontics2004; 1: 53–62.
5.
CopeJBTemporary anchorage devices in orthodontics: a paradigm shift. Semin Orthod2005; 11: 3–9.
6.
BranemarkPI, AdellR, BrieneU, HanssonBO, LindstromJ, OhlssonAIntra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg1969; 3: 81–100.
7.
RobertsWE, SmithRK, ZilbermanY, MozsaryPG, SmithRSOsseous adaptation to continuous loading of rigid endosseous implants. Am J Orthod1984; 86: 95–111.
8.
RobertsWE, HelmFR, MarshallKJ, GongloffRKRigid endosseous implants for orthodontic and orthopaedic anchorage. Angle Orthod1989; 59: 247–56.
9.
HiguchiKW, SlackJMThe use of titanium fixtures for intraoral anchorage to facilitate orthodontic tooth movement. Int J Oral Maxillofac Implants1991; 6: 338–344.
10.
OdmanJ, LekholmU, JemT, ThilanderBOsseointegrated implants as orthodontic anchorage in the treatment of partially edentulous adult patients. Eur J Orthod1994; 16: 187–201.
11.
WehrbeinH, MerzBR, DiedrichP, GlatzmaierJThe use of palatal implants for orthodontic anchorage. Design and clinical application of the Orthosystem. Clin Oral Implants Res1996; 7: 410–16.
12.
BernhartT, VollgruberA, GahleiterA, DortbudakO, HaasRAlternative to the median region of the palate for placement of an orthodontic implant. Clin Oral Implants Res2000; 11: 595–601.
13.
TrisiP, RebaudiAProgressive bone adaptation of titanium implants during and after orthodontic load in humans. Int J Periodont Restorative Dent2002; 22: 31–43.
14.
RobertsWE, MarshallKJ, MozsaryPGRigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site. Angle Orthod1990; 60: 135–52.
15.
MelsenB, CostaAImmediate loading of implants used for orthodontic anchorage. Clin Orthod Res2000; 3: 23–28.
16.
OhmaeM, SaitoS, MorohashiT, SekiK, QuH, KanomiR, OkanoT, YamadaS, ShibasakiYA clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog. Am J Orthod Dentofacial Orthop2001; 119: 489–97.
17.
DeguchiT, Takano-YamamotoT, KanomiR, HartsfieldJK, RobertsWE, GarettoLP. The use of small titanium screws for orthodontic anchorage. J Dent Res2003; 82: 377–81.
CostaA, RaffainiM, MelsenBMiniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthod Orthognath Surg1998; 13: 201–09.
20.
JennerJD, FitzpatrickBNSkeletal anchorage utilizing bone plates. Aust Orthod J1985; 9: 231–33.
21.
UmemoriM, SuguwaraJ, MitaniH, NagasakaH, KawamuraHSkeletal anchorage system for open-bite correction. Am J Orthod Dentofacial Orthop1999; 115: 166–74.
22.
FreudenthalerJW, BantleonHP, HaasRBicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications. Clin Oral Implants Res2001; 12: 358–63.
23.
MiyawakiS, KoyamaI, InoueM, MishimaK, SugaharaT, Takano-YamamotoT.Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop2003; 124: 373–78.
24.
ChoiBH, ZhuSJ, KimYHA clinical evaluation of titanium miniplates as anchors for orthodontic treatment. Am J Orthod Dentofacial Orthop2005; 128: 382–84.
25.
FaveroL, BrolloP, BressanEOrthodontic anchorage with specific fixtures: related study analysis. Am J Orthod Dentofacial Orthop2002; 122: 84–94.
26.
CaranoA, LonardoP, VeloS, IncorvatiCMechanical properties of three different commercially available miniscrews for skeletal anchorage. Prog Orthod2005; 6: 82–97.
KimJW, AhnSJ and ChangYII. Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage. Am J Orthod Dentofacial Orthop2005; 128: 190–4.
29.
HiedemannW, TerheydenH, GerlachKLAnalysis of the osseous/metal interface of drill free screws and self-tapping screws. J Craniomaxillofac Surg2001; 29: 69–74.
30.
WehrbeinH, FeifelH, DiedrichPPalatal implant anchorage reinforcement of posterior teeth: a prospective study. Am J Orthod Dentofacial Orthop1999; 116: 678–86.
31.
IshiiT, NojimaK, NishiiY, TakakiT, YamaguchiHEvaluation of the implantation position of mini-screws for orthodontic treatment in the maxillary molar area by a micro CT. Bull Tokyo Dent Coll2004; 45: 165–72.
32.
CousleyRCritical aspects in the use of orthodontic palatal implants. Am J Orthod Dentofacial Orthop2005; 127: 723–29.
33.
SchlegelKA, KinnerF, SchlegelKDThe anatomic basis for palatal implants in orthodontics. Int J Adult Orthodon Orthognath Surg2002; 17: 133–39.
34.
CostaA, PastaG, BergamaschiGIntraoral hard and soft tissue depths for temporary anchorage devices. Semin Orthod2005; 11: 10–15.
35.
PoggioPM, IncorvatiC, VeloS, CaranoA‘Safe zones’: a guide for microscrew positioning in the maxillary and mandibular arch. Angle Orthod2006; 76: 191–97.
36.
SchnelleMA, BeckFM, JaynesRM, HujaSSA radiographic evaluation of the availability of bone for placement of miniscrews. Angle Orthod2004; 74: 832–37.
37.
LiouEJW, PaiBCJ, LinJCY. Do miniscrews remain stationary under orthodontic forces?Am J Orthod Dentofacial Orthop2004; 126: 42–47.
38.
AsscherickxK, VannetBV, WehrbeinH, SabzevarMMRoot repair after injury from mini-screw. Clin Oral Implants Res2005; 16: 575–78.
39.
FukunagaT, KurodaS, KurosakaH, Takano-YamamotoT.Skeletal anchorage for orthodontic correction of maxillary protrusion with adult periodontitis. Angle Orthod2006; 76: 148–55.
40.
LondaGThe anchorage quality of titanium microplates with short microscrews for orthodontic anchorage applications. J Orofac Orthop2005; 66: 67–77.
41.
WehrbeinH, MerzBR, DiedrichPPalatal bone support for orthodontic implant anchorage—a clinical and radiological study. Eur J Orthod1999; 21: 65–70.
42.
TosunT, KelesA, ErverdiNMethod for the placement of palatal implants. Int J Oral Maxillofac Implants2002; 17: 95–100.
43.
MartinW, HeffernanN, RuskinJTemplate fabrication for a midpalatal orthodontic implant: technical note. Int J Oral Maxillofac Implants2002; 17: 720–22.
KitaiN, YasudaY, TakadaKA stent fabricated on a selectively colored stereolithographic model for placement of orthodontic mini-implants. Int J Adult Orthodon Orthognath Surg2002; 17: 264–66.
49.
MoreaC, DominguezGC, WuoADV, TortamanoA., Surgical guide for optimal positioning of mini-implants. J Clin Orthod2005; 39: 317–21.
50.
CousleyRRJ, ParberryDJ., Surgical stents for accurate miniscrew insertion. J Clin Orthod2006; 40: 412–17.
51.
LaskinDM, DentCD, MorrisHF, OchiS, OlsonJWThe influence of preoperative antibiotics on success of endosseous implants at 36 months. Ann Periodontol2000; 5: 166–74.
52.
MahJ, BergstrandFTemporary anchorage devices: a status report. J Clin Orthod2005; 39: 132–36.
53.
LambertPM, MorrisHF, OchiSThe influence of 0.12% chlorhexidine digluconate rinses on the incidence of infectious complications and implant success. J Oral Maxillofac Surg1997; 55: 25–30.
54.
MotoyoshiM, HirabayashiM, UemuraM, ShimizuNRecommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res2006; 17: 109–14.
55.
FornaN, BurluiV, LucaIC, IndreiAPeri-implantitis. Rev Med Chir Soc Med Nat Iasi1998; 102: 74–79.
56.
ChengSJ, TsengIY, LeeJJ, KokSHA prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants2004; 19: 100–06.
57.
MelsenB, LangNPBiological reactions to orthodontic loading of oral implants. Clin Oral Implants Res2001; 12: 144–52.
58.
DuyckJ, RonoldHJ, Van OosterwyckHThe influence of static and dynamic loading on marginal bone reactions around osseo-integrated implants: an animal experimental study. Clin Oral Implants Res2001; 12: 207–18.
59.
WehrbeinH, HovelP, KinzingerG, StefanBLoad-deflection behaviour of transpalatal bars supported on orthodontic palatal implants. An in vitro study. J Orofac Orthop2004; 65: 312–20.
60.
MotoyoshiM, YanoS, TsuruokaT, ShimuzuNBiomechanical effect of abutment on stability of orthodontic mini-implant. Clin Oral Implants Res2005; 16: 480–85.