JobsisF. Non invasive, infrared monitoring of cerebral and myocardial oxygen insufficiency and circulation parameters. Science1977; 198: 1264–7
4.
WyattJSCopeMDelpyDRichardsonCEdwardsADWrayS. Quantitation of cerebral blood volume in human infants by near infrared spectroscopy. J Appl Physiol1990; 68: 1086–91
5.
BauerBFloydTA. Monitoring of glucose in biological fluids by Fourier-transform infrared spectrometry with a cylindrical internal reflectance cell. Analyt Chim Acta1987; 197: 295–301
6.
LoydDRRawashdehMOBoothIWBrownGA. The steatocrit: An improved procedure. Ann Clin Biochem1992; 29: 535–40
7.
YamauchiYKhashabaMMagamiRYamanouchiI. Near infrared spectroscopy for screening and estimating total faecal lipid content in early infancy. In: TakasugiNNaruseH, eds. New Trends in Neonatal Screening.Sapporo: Hokkaido University Press, 1994
8.
BeniniLCaliariSGuidiBVaonaBTalaminiGVantiniI. Near IR spectrometry for faecal fat measurement: Comparison with conventional gravimetric and titrimetric methods. Gut1989; 30: 1344–7
9.
CornsCM. Infrared analysis of renal calculi: Comparison with conventional techniques. Ann Clin Biochem1983; 20: 20–5
10.
AkiyamaTYamauchiY. Use of near infrared reflectance spectroscopy in the screening for biliary atresia. J Pediatr Surg1994; 29: 645–7
11.
SfezMDesruellePPennecotGF, Cohen-Bacrie P, Boulogne-Billancourt B. Intérêt de la mesure peropératoire de la concentration d'hémoglobine. Evaluation d'une méthode colorimétrique. Cah Anesthesiol1991; 39: 247–51
12.
SimpsonWGRossJRossS. Near IR spectral analysis in-vivo: rapid non-invasive measurement of glucose and HbAlc in a clinical setting [Poster presentation 652]. Diabetologia1994; 37(suppl 1): A169
13.
RobinsonMREatonRPHaalandDMKoeppGWThomasEVStallardBR. Noninvasive glucose monitoring in diabetic patients: A preliminary evaluation. Clin Chem1992; 38: 1618–22
14.
KajiwaraKUemuraTKishikawaHNishidaKHashiguchiYUeharaM. Non-invasive measurement of blood glucose concentrations using FTIR spectra through the oral mucosa. Med Biol Engng Comput1993; 31(suppl): 17–22
15.
KajiwaraKFukushimaHUemuraTKishikawaHNishidaKHashiguchiY. Spectroscopic quantitative analysis of blood glucose by FTIR spectroscopy with an attenuated total internal reflection prism. Med Prog Technol1992; 18: 181–9
16.
QuanKMChristisonGBMacKenzieHAHidgsonP. Glucose determination by a pulsed photoacoustic technique, an experimental study using a gelatin-based phantom. Phys Med Biol1993; 38: 1911–22
17.
MarbachRKochinskyTGriesFHeiseH. Non invasive blood glucose assay by near IR diffuse reflectance spectroscopy of the human inner lip. Spectroscopy1993; 47: 875–81
18.
ArnoldMASmallGW. Determination of physiological levels of glucose in an aqueous matrix with digitally filtered FTIR spectra. Anal Chem1990; 62: 1457–64
19.
KaiserN. Laser absorption spectroscopy with an ATR Prism. IEEE Trans Biomed Engng1979; 26: 597–600
20.
MendelsonYClermontACPeuraRALinBC. Blood glucose measurement by multiple attenuated total reflection and IR absorption spectra. IEEE Trans Biomed Engng1990; 37: 458–65
21.
RobinsonRJMcDonaldSD. Glucose-sensitive membrane and IR absorption spectroscopy for potential use as an implantable glucose sensor. ASAIO J1992; 38: 458–62
22.
HeiseHMMarbachRJanatschGKruse-JarresJD. Multivariate determination of glucose in whole blood by attenuated total reflection IR spectroscopy. Anal Chem1989; 61: 2009–15
23.
JanatschGKruse-JarresJDMarbachRHeiseHM. Multivariate calibration for assays in clinical chemistry using attenuated total reflection IR spectra of human blood plasma. Anal Chem1989; 61: 2016–23
24.
ZellerHNovakPLandgrafR. Blood glucose measurement by IR spectroscopy. Int J Artif Organs1989; 12: 129–35
25.
SmallGWArnoldMAMarquardtLA. Strategies for coupling digital filtering with partial least-squares regression: Application to the determination of glucose in plasma by FTIR spectroscopy. Anal Chem1993; 65: 3279–89
26.
MarquardtLAArnoldMASmallGW. Near infra red spectroscopic measurement of glucose in a protein matrix. Anal Chem1993; 65: 3271–8
27.
HallJWPollardANearIR. Spectroscopic determination of serum total proteins, albumin, globulins and urea. Clin Biochem1993; 26: 483–90
28.
BeniniLCaliariSBonfanteFGuidiGCBrenteganiMTCastellaniG. Near infra red reflectance measurement of nitrogen faecal losses. Gut1992; 33: 749–52
29.
De BlasiRACopeMElwellCSafoueFFerrariM. Non-invasive measurement of human forearm oxygen consumption by near IR spectroscopy. Eur J Appl Physiol1993; 67: 20–5
30.
DelpyDTCopeMvan der ZeePArridgeSWraySWyattJ. Estimation of optical pathlength through tissue from direct time of flight measurement. Phys Med Biol1988; 33: 1433–42
31.
du PlessisAJNeubergerJJonasRAHickeyPNaruseHTsujiM. Cerebral oxygen supply utilisation during infarct cardiac surgery. Ann Neurol1995; 37: 488–97
32.
SoreideRDracupBSvarstadE, Iverson BM. Increased body fat during PD treatment. Adv Peril Dial1992; 8: 173–6
33.
KeshaviahPRNolphKDMooreHLProwantBEmersonPFMeyerM. Lean body mass estimation by creatinine kinetics. J Am Soc Nephrol1994; 4: 1475–85