Abstract
BACKGROUND:
At present, there are few studies related to mean nocturnal baseline impedance (MNBI), esophageal dynamic reflux monitoring, high-resolution esophageal manometry (HRM) parameter indexes, and its diagnostic value in gastroesophageal reflux disease (GERD).
OBJECTIVE:
To analyze the factors influencing MNBI and examine the diagnostic value of MNBI in GERD.
METHODS:
A retrospective analysis on 434 patients with typical reflux symptoms who underwent gastroscopy, 24-hour multichannel intraluminal impedance and pH monitoring (MII/pH) and HRM. They were divided into the conclusive evidence group (103 cases), borderline evidence group (229 cases), and exclusion evidence group (102 cases) according to the level of diagnostic evidence of GERD based on the Lyon Consensus. We analyzed the differences in MNBI, esophagitis grade, MII/pH and HRM index among the groups; the correlation between MNBI and the above indexes and its influence on MNBI; and to evaluate the diagnostic value of MNBI in GERD.
RESULTS:
There were significant differences in MNBI, Acid Exposure Time (AET) 4%, DeMeester score, and total reflux episodes among the three groups (
CONCLUSION:
AET, EGJ-CI, and esophagitis grade are the most important influence factors of MNBI. MNBI has good diagnostic value in identifying conclusive GERD.
Keywords
Get full access to this article
View all access options for this article.