Abstract
OBJECTIVE:
TO measure epoetin alfa concentrations after adding it to a variety of commonly used neonatal intravenous fluids to determine the stability of epoetin alfa over time.
DESIGN:
Epoetin alfa was added to the following fluids: sterile water; NaCl 0.9%; dextrose 10% in water; dextrose 10% with albumin at concentrations of 0.01 %, 0.05%, and 0.1 %; and total parenteral nutrition solution containing either 0.5% or 2.25% amino acids. The fluid was administered through intravenous tubing, a T-connector, and catheter, and samples were collected at 0,2,4, 8, and 24 hours.
MAIN OUTCOME MEASURES:
Epoetin alfa concentrations were compared with the measured original preinfusion concentration and recorded as the percentage recovered.
RESULTS:
Concentrations declined significantly in all fluids containing less than 0.05% protein, but remained stable over 24 hours in fluids containing 0.05% or more protein.
CONCLUSIONS:
We conclude that epoetin alfa should be mixed in intravenous fluids containing at least 0.05% protein.
Get full access to this article
View all access options for this article.