Since the systemic drugs have been used to reduce the hyperplasic response in the tunica intima, the periadventitial local drug applications to the vascular wall have gained more popularity. In this study, we investigated the effect of bovine serum albumin-glutaraldehyde and polyethylene glycol polymer on neointimal hyperplasia in rabbit carotid artery anastomosis to explore the effects of these two different agents.
Methods
21 New Zealand male rabbits were randomly divided into three groups. The carotid artery transection and anastomosis was performed onthe control group. The bovine serum albumin-glutaraldehyde and the polyethylene glycol polymer were applied locally on the other two groups seperatley after transection and anastomosis of the carotid arteries. At the end of 28-day follow-up, the histological and the immunohistochemical results related to neointimal hyperplasia were compared.
Results
The glue residues were detected in the BSA-glutaraldehyde group, but in the PEG polymer group there was no glue residue. The intima thickness and the intima/media thickness ratio in the control group was significantly higher (p<0.05) than the other groups. These values did not differ significantly between the BSA-glutaraldehyde group and the PEG polymer group (p>0.05). The lumen diameter and the area in the control group were significantly higher (p < 0.05) than the BSA-glutaraldehyde group. These values between the control group and the PEG polymer group did not differ significantly (p>0.05). aSMA-positive staining score in the Control group was found to be significantly lower (p < 0.05) than the BSA-glutaraldehyde and PEG polymer group and the VEGF-positive staining score in the control group was found to be significantly higher (p < 0.05) than the BSA-glutaraldehyde and the PEG polymer group.
Conclusions
Although the both agents have positive results on neointimal hyperplasia, it would be favorable to use polyethylene glycol polymer, since it does not seem to affect the lumen area and the lumen diameter of the vessel.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.