GomesA., HallinanJ.Intravenous digital subtraction angiography in the diagnosis of brain death. AJNR1983; 4: 21–24.
5.
KricheffI.I., PintoR.S., GeorgeA.E., BraunsteinP., KoreinJ.Angiographic findings in brain death. Ann N Y Acad Sci1978; 315: 168–83.
6.
VatneK.P.N., LundarT.Digital subtraction angiography (DSA) in the evaluation of brain death. A comparison of conventional cerebral angiography with intravenous and intraarterial DSA. Neuroradiology1985; 27: 155–157.
SchwartzJ.A., BaxterJ., BrillD.R.Diagnosis of brain death in children by radionuclide cerebral imaging. Pediatrics1984; 73: 14–8.
9.
KoreinJ., BraunsteinP., KricheffI., LiebermanA., ChaseN.Radioisotopic bolus technique as a test to detect circulatory deficit associated with cerebral death. 142 studies on 80 patients demonstrating the bedside use of an innocuous IV procedure as an adjunct in the diagnosis of cerebral death. Circulation1975; 51: 924–39.
10.
TanW.S., WilburA.C., JafarJ.J., SpigosD.G., AbejoR.Brian death: use of dynamic CT and intravenous digital subtraction angiography. AJNR1987; 8: 123–5.
11.
KoreinJ., BraunsteinP., GeorgeJ., WichterM.Brain death: I. Angiographic correlation with the radioisotope bolus technique for evaluation of critical deficit of cerebral blood flow. Ann Neurol1977; 2: 195–205.
12.
RosenklintA., JorgensenP.Evaluation of angiographic methods in the diagnosis of brain death. Correlation with local and systemic arterial pressure and intracranial pressure. Neuroradiology1974; 7: 215–219.
13.
BradacG., SimonR.Angiography in brain death. J Neurorad1974; 7: 25–28.
HeiskanenO.Cerebral circulatory arrest caused by acute increase of intracranial pressure. A clinical and roentgenological study of 25 cases. Acta Neurol Scand (Suppl)1964; 7: 1–57.
16.
ArnoldH., KuhneD., RohrW., HellerM.Contrast bolus technique with rapid CT scanning a reliable diagnostic tool for the determination of brain death. Neuroradiology1981; 22: 129–132.
17.
VanBunnenY., DelcourC., WeryD.Intravenous digital subtraction angiography: a criterion of brain death. Ann Radiol1989; 32: 279–281.
18.
JeffersonN.Further aspects of angiographic brain death. Australas Radiol1975; 19: 289–296.
19.
Van-VelthovenV., CalliauwL.Diagnosis of brain death. Transcranial Doppler sonography as an additional method. Acta Neurochir1988; 95: 57–60.
20.
TsaiS.H., CranfordR.E., RockswoldG.L., KoehlerS.Cerebral radionuclide angiography. Its application in the diagnosis of brain death. JAMA1982; 248: 591–2.
21.
CowenR.J.Conventional radionuclide brain imaging in the era of transmission and emission tomography. Semin Nucl Med1986; 16: 63–73.
GoodmanJ.M., HeckL.L., MooreB.D.Confirmation of brain death with portable isotope angiography: a review of 204 consecutive cases. Neurosurgery1985; 16: 492–7.
24.
NagleC.E.Use of immediate static scans in combination with radionuclide cerebral angiography as a confirmatory test in the diagnosis of brain death. Clin Nucl Med1980; 5: 152–3.
25.
MishkinF.Determination of cerebral death by radionuclide angiography. Radiology1975; 115: 135–137.
26.
GoodmanJ.M., MishkinF.S., DykenM.Determination of brain death by isotope angiography. JAMA1969; 209: 1869–72.
27.
GoodmanJ.M., HeckL.L.Confirmation of brain death at bedside by isotope angiography. JAMA1977; 238: 996–8.
28.
MishkinF.Brain scanning in children. Semin Nucl Med1972; 2: 328–42.
MishkinF.Death and “brain death”. N Engl J Med1978; 299: 1313–1314.
31.
BrillD.R., SchwartzJ.A., BaxterJ.A.Variant flow patterns in radionuclide cerebral imaging performed for brain death. Clin Nucl Med1985; 10: 346–52.
32.
AshwalS., SmithA.J., TorresF., LokenM., ChouS.N.Radionuclide bolus angiography: a technique for verification of brain death in infants and children. J Pediatr1977; 91: 722–7.
33.
BurkhalterJ.L., PatelB.R.Radiological seminar CCXXIV: Radionuclide cerebral angiography and brain death. J Miss State Med Assoc1982; 23: 258–60.
HolzmanB.H., CurlessR.G., SfakianakisG.N., Ajmone-MarsanC., MontesJ.E.Radionuclide cerebral perfusion scintigraphy in determination of brain death in children. Neurology1983; 33: 1027–31.
36.
PearsonJ., KoreinJ., HarrisJ., WichterM., BraunsteinP.Brain death: II. Neuropathological correlation with the radioisotopic bolus technique for evaluation of critical deficit of cerebral blood flow. Ann Neurol1977; 2: 206–210.
37.
RivaA., GonzalezF., Llamas-ElviraJ.A diagnosis of brain death: Superiority of perfusion studies with Tc-99m HMPAO over conventional radionuclide cerebral angiography. Br J Radiol1992; 65: 289–294.
38.
SpiethM., AnsariA., KawadaT., SiegelM.Comparison of DTPA and HMPAO for the evaluation of brain death. J Nucl Med1991; 32: 1839.
39.
LeeV.W., HauckR.M., MorrisonM.C.Scintigraphic evaluation of brain death: significance of sagittal sinus visualization. J Nucl Med1987; 28: 1279–83.
40.
LaurinN.R., DriedgerA.A., HurwitzG.A.Cerebral perfusion imaging with technetium-99m HM-PAO in brain death and severe central nervous system injury [see comments]. J Nucl Med1989; 30: 1627–35.
41.
CokerS.B., DellehayG.L.Radionuclide cerebral imaging for confirmation of brain death in children: the significance of dural sinus activity. Pediatr Neurol1986; 2: 43–6.
42.
AlvarezL.A., LiptonR.B., HirschfeldA., SalamonO., LantosG.Brain death determination by angiography in the setting of a skull defect. Arch Neurology1988; 45: 225–7.
43.
HansenA.V., LavinP.J., MoodyE.B., SandlerM.P.False-negative cerebral radionuclide flow study, in brain death, caused by a ventricular drain. Clin Nucl Med1993; 18: 502–5.
44.
de-la-RivaA., GonzalezF.M., Llamas-ElviraJ.M.Diagnosis of brain death: superiority of perfusion studies with 99Tcm-HMPAO over conventional radionuclide cerebral angiography. Br J Radiol1992; 65: 289–94.
45.
GalaskeR.G., SchoberO., HeyerR.99mTc-HM-PAO and 1231-amphetamine cerebral scintigraphy: a new, non invasive method in determination of brain death in children. Eur J Nucl Med1988; 14: 446–52.
46.
GalaskeR.G., SchoberO., HeyerR.Determination of brain death in children with 1231-IMP and Tc-99m HMPAO. Psychiatry Res1989; 29: 343–5.
47.
LararG.N., NagelJ.S.Technetium-99m-HMPAO cerebral perfusion scintigraphy: considerations for timely brain death declaration [Comments]. J Nucl Med1992; 33: 2209–11.
48.
WilsonK., GordonL., SelbyJBSrThe diagnosis of brain death with Tc-99m HMPAO. Clin Nucl Med1993; 18: 428–34.
49.
SchlakeH.P., BottgerI.G., GrotemeyerK.H.Determination of cerebral perfusion by means of planar brain scintigraphy and 99mTc-HMPAO in brain death, persistent vegetative state and severe coma. Intens Care Med1992; 18: 76–81.
50.
YatimA., MercatelloA., CoronelB.99mTc-HMPAO cerebral scintigraphy in the diagnosis of brain death. Transplant Proc1991; 23: 2491.
51.
CostaD.C., MotteuxI.M., McCreadyA.C.Diagnosis of brain death with technetium 99m hexamethylpropylene amine oxime. Eur J Nucl Med1991; 18: 503–6.
52.
ReidR.H., GulenchynK.Y., BallingerJ.R.Clinical use of technetium-99m HM-PAO for determination of brain death. J Nucl Med1989; 30: 1621–6.
53.
RoineR.O., LaunesJ., LindrothL., NikkinenP.99mTc-hexamethylpropyleneamine oxime scans to confirm brain death (letter). Lancet1986; 2: 1223–4.
54.
RoineR.O., LaunesJ., LindrothL., NikkinenP.Brain death and cerebral blood flow (letter). Lancet1987; 1: 46–7.
55.
BrandauW., SchoberO., KnappW.H.Determination of brain death with technetium-99m-HMPAO [Letter; Comment]. J Nucl Med1990; 31: 2075–6.
56.
SchoberO., GalaskeR., HeyerR.Determination of brain death with 1231-IMP and 99mTc-HM-PAO. Neurosurg Rev1987; 10: 19–22.
57.
WielerH., MarohlK., KaiserK.P., KlawkiP., FrosslerH.Tc-99m HMPAO cerebral scintigraphy. A reliable, noninvasive method for determination of brain death. Clin Nucl Med1993; 18: 104–9.
58.
ValleG., CiritellaP., BonettiM.G., DicembrinoF., PerroneE., PernaG.P.Considerations of brain death on a SPECT cerebral perfusion study. Clin Nucl Med1993; 18: 953–4.
59.
LewisR., PadayacheeT., BeasleyM., KeenH.Investigation of brain death with Doppler-shift ultrasound. J R Soc Med1983; 76: 3308–310.
60.
FeriM., RalliL., FeliciM., VanniD., CapriaV.Transcranial Doppler and brain death diagnosis. Crit Care Med1994; 22: 1120–6.
61.
ZurynskiY., DorschN., PearsonI., ChoongR.Transcranial Doppler ultrasound in brain death: experience in 140 patients. Neurological Research1991; 13: 248–52.
62.
WallashT.M., ReineckeM.Transcranial Doppler in brain death [Letter; Comment]. Neurology1990; 40:.
63.
PayenD.M., LamerC., PilorgetA.Evaluation of pulsed Doppler common carotid blood flow as a noninvasive method for brain death diagnosis: a prospective study. Anesthesiology1990; 72: 222–9.
64.
PettyG.W., MohrJ.P., PedleyT.A.The role of transcranial Doppler in confirming brain death: sensitivity, specificity, and suggestions for performance and interpretation. Neurology1990; 40: 300–3.
65.
DernbachP.D.Transcranial Doppler determination of brain death [Letter). Neurosurgery1989; 25:.
66.
GawlowskiJ., HasslerW.Is TC-Doppler sonography a useful method for the determination of brain death?Neurosurgical Review1989; 1: 307–10.
67.
RiesF., MoskoppD.Value of the transcranial Doppler ultrasound technique (TCD) for the determination of brain death. Neurosurg Review1989; 1: 302–6.
68.
HardersA.Atraumatic estimation of blood flow arrest in the diagnosis of cerebral death with the transcranial Doppler investigation technique. Neurosurg Review1989; 1: 298–301.
69.
KirkhamF.J., NevilleB.G., GoslingR.G.Diagnosis of brain death by transcranial Doppler sonography (Letter; Comment). Archives of Dis Childhood1989; 64: 889–90.
70.
GlasierC.M., SiebertJ.J., ChadduckW.M., WilliamsonS.L., LeithiserR.Jr.Brain death in infants: evaluation with Doppler US. Radiology1989; 172: 377–80.
71.
HasslerW., SteinmetzH., PirschelJ.Transcranial Doppler study of intracranial circulatory arrest. J Neurosurg1989; 71: 195–201.
72.
NewellD.W., GradyM.S., SirrotaP., WinnH.R.Evaluation of brain death using transcranial Doppler. Neurosurgery1989; 24: 509–13.
73.
PilayP.K., WilbergerJ.Transcranial Doppler evaluation of brain death (Letter). Neurosurgery1989; 25: 481–2.
74.
PowersA.D., GraeberM.C., SmithR.R.Transcranial Doppler ultrasonography in the determination of brain death. Neurosurgery1989; 24: 884–9.
75.
BodeH., SauerM., PringsheimW.Diagnosis of brain death by transcranial Doppler sonography. Arch Dis Childhood1988; 63: 1474–8.
76.
VanV.V., CalliauwL.Diagnosis of brain death. Transcranial Doppler sonography as an additional method. Acta Neurochirurg1988; 95: 57–60.
77.
HasslerW., SteinmetzH., GawlowskiJ.Transcranial Doppler ultrasonography in raised intracranial pressure and in intracranial circulatory arrest. J Neurosurgery1988; 68: 745–51.
78.
AhmannP.A., CarriganT.A., CarltonD., WylyB., SchwartzJ.F.Brain death in children: characteristic common carotid arterial velocity patterns measured with pulsed Doppler ultrasound. J Pediatrics1987; 110: 723–8.
RopperA.H., KehneS.M., WechslerL.Transcranial Doppler in brain death. Neurology1987; 37: 1733–5.
81.
McMenaminJ.B., VolpeJ.J.Doppler ultrasonography in the determination of neonatal brain death. Ann Neurology1983; 14: 302–7.
82.
LewisR.R., PadayacheeT.S., BeasleyM.G., KeenH., GoslingR.G.Investigation of brain death with Doppler-shift ultrasound. 1 Roy Soc Med1983; 76: 308–10.
83.
YonedaS., NishimotoA., NukadaT., KuriyamaY., KatsuradaK.To-and-fro movement and external escape of carotid arterial blood in brain death cases. A Doppler ultrasonic study. Stroke1974; 5: 707–13.
84.
RangelR.Computerized axial tomography in brain death. Stroke1978; 9: 597–598.
85.
RappaportZ., BrinkerR., RovitR.Evaluation of brain death by contrast-enhanced computerized cranial tomography. Neurosurgery1978; 2: 230–22.
86.
WalkerA.E.Ancillary studies in the diagnosis of brain death. Ann N Y Acad Sci1978; 315: 228–40.
87.
ThompsonJ.R., AshwalS., SchneiderS.Comparison of cerebral blood flow measurements by xenon computed tomography and dynamic brain scintigraphy in clinically brain dead children. Acta Radiol Suppl1986; 369: 675–9.
88.
JohnsonD.W., StringerW.A., MarksM.P.Stable xenon CT cerebral blood flow imaging: rationale for and rule in clinical decision making. Am J Neuroradiol1991; 12: 201–13.
89.
PistoiaF., JohnsonD.W., DarbyJ.M.The role of xenon CT measurements of cerebral blood flow in the clinical determination of brain death. Am J Neuroradiol1991; 12: 97–103.
AshwalS., SchneiderS., ThompsonJ.Xenon computed tomography measuring cerebral blood flow in the determination of brain death in children. Ann Neurol1989; 25: 539–546.
92.
JonesK.M., BarnesP.D.MR Diagnosis of brain death. Am J Neuroradiol1992; 13: 65–6.
93.
AichnerF., FelberS., BirbamerG.Magnetic resonance: a noninvasive approach to metabolism, circulation, and morphology in human brain death. Ann Neurology1992; 32: 507–11.
94.
GardeK., MortensenA.C., ToftP.B.Phosphorous and proton spectroscopy in relation to near incarceration and incarceration in the human brain. Acta Radiol1994; 35: 197–200.
95.
TerkM.R., GoberJ.R., DeGiorgioC.Brain death in the neonate: assessment with P-31 MR spectroscopy [Letter; Comment]. Radiology1992; 182: 582–3.
96.
KatoT., TokumaruA., O'uchiT.Assessment of brain death in children by means of P-31 MR spectroscopy: preliminary note. Work in progress. Radiology1991; 179: 95–9.
97.
MomoseT., NishikawaJ., WatanabeT.Clinical application of 18F-FDG-PET in patients with brain death. Kaku Igaku. Jap J Nuclear Med1992; 29: 1139–42.