MorrisonRBIDavisonJMKerrDNS. Clinical physiology of the kidney: Tests of renal function and structure. In: WeatherallDJLedinghamJGGWarrellDA, eds. Oxford Textbook of Medicine, 2nd edn.Oxford: OUP, 1987; 18. 1–17.
11.
RallsJO. Urea is not equally distributed between water of blood cells and that of plasma. J Biol Chem1943; 151: 529–41.
12.
MurdaughHVJrDoyleEM. Effect of hemoglobin on erythrocyte urea concentration. J Lab Clin Med1961; 57: 759–62.
13.
DigiorgioJ.Non-protein nitrogenous constituents other than amino acids. In: HenryRJCannonDCWinkelmanJW, eds. Clinical Chemistry: Principles and Technics. Maryland: Harper and Row1974; 503–64.
14.
YoungDSPestanerLCGibbermanV.Effects of drugs on clinical laboratory tests. Clin Chem1975; 21: 371D–73D.
15.
SampsonEJBairdMABurtisCASmithEMWitteDLBayseDD. A coupled-enzyme equilibrium method for measuring urea in serum: Optimization and evaluation of the AACC Study Group on urea candidate reference method. Clin Chem, 1980; 26: 816–26.
16.
PrytzBGrossiCERousselotLM. In vitro formation of ammonia in blood of man and dog. Clin Chem1970; 16: 277–9.
17.
BaileyIR. Effect on 16 analytes of overnight storage of specimens collected into heparinised evacuated tubes with plasma separator. Ann Clin Biochem1990; 27: 56–8.
18.
FraserCG. The collection, transportation and storage of specimens. In: WilliamsDLMarksV, eds. Principles of Clinical Biochemistry: Scientific Foundations. Oxford: Heinemann, 1988; 30–5.
19.
RileyWJ. Normal values, reference ranges and decision points. Clin Biochem Revs1987; 8: 5–10.
JosephsonBFurstPJarnmarkO.Age variations in the concentrations of non-protein nitrogen creatinine and urea in blood of infants and children. Acta Paediatr1962; 51 (Suppl 135): 111–20.
24.
BjornesjoKB. The distribution of alpha-amino nitrogen, urea nitrogen and non-protein nitrogen between erythrocytes and plasma in healthy males and females. Scand J Clin Lab Invest1963; 15 (Suppl 69): 25–37.
25.
GowenlockAHBroughtonPMG. The influence of accuracy and precision on the normal range and on acceptable limits for an analytical result. Fresenius’ Z Anal Chem1968; 243: 774–80.
26.
WinkelPStatlandPEBokelundH.The effects of time of venepuncture on variation of serum constituents: Consideration of within-day and day-to-day changes in a group of healthy young men. Am J Clin Pathol1975; 64: 433–7.
27.
WinkelPBokelundHStatlandBE. Factors contributing to intra-individual variation of serum constituents in healthy subjects. Clin Chem1974; 20: 1520–7.
28.
HarrisEKKanofskyPShakarjiGCotloveE.Biological and analytical components of variation in long-term studies of serum constituents in normal subjects: 2. Estimating biological components of variation. Clin Chem1970; 16: 1022–7.
29.
YoungDSHarrisEKCotloveE.Biological and analytical components of variation in long-term studies of serum constituents in normal subjects: 4. Results of a study designed to eliminate long-term analytical deviations. Clin Chem1971; 17: 403–10.
30.
FraserCG. Desirable performance standards for clinical laboratory tests. In: LatnerALSchwartzMK, eds. Advances in Clinical Chemistry, Vol. 23. New York: Academic Press, 1983; 300–40.
31.
StatlandBE. The relationship of biological variation and clinical decision levels to quality assurance. In: BoutwellJH, ed. Quality Assurance in Health Care: A Critical Appraisal of Clinical Chemistry. Washington: American Association for Clinical Chemistry, 1980; 125–33.
32.
FraserCGHearneCR. Components of variance of some plasma constituents in patients with myocardial infarction. Ann Clin Biochem1982; 19: 431–4.
33.
FraserCGWilliamsP.Short-term biological variation of plasma analytes in renal disease. Clin Chem1983; 29: 508–10.
34.
PickupJFHarrisEKKearnsMBrownSS. Intraindividual variation of some serum constituents and its relevance to population-based reference ranges. Clin Chem1979; 23: 842–50.
35.
HarrisEKBrownSS. Temporal changes in the concentration of serum constituents in healthy men. Ann Clin Biochem1979; 16: 169–76.
ElevitchFR. Analytical goals in clinical chemistry: Their relationship to medical care. Proceedings of the Subcommittee on Analytical Goals in Clinical Chemistry, World Association of Societies of Pathology, London, England. Am J Clin Pathol1979; 71: 624–30.
38.
FraserCG. Analytical goals for glucose analyses. Ann Clin Biochem1986; 23: 379–89.
39.
TonksDB. A study of the accuracy and precision of clinical chemistry determinations in 170 Canadian laboratories. Clin Chem1963; 9: 217–23.
40.
StevensJFCresswellMA. Achievable standards of laboratory performance. News Street of the Association of Clinical Biochemists1978; 182: 12–13.
41.
StevensJCresswellMA. Achievable standards of laboratory performance. News Street of the Association of Clinical Biochemists1979; 197: 14–15.
42.
StevensJCresswellMA. Achievable standards of laboratory performance. News Street of the Association of Clinical Biochemists1982; 227: 4–6.
43.
StevensJ.Achievable standards of laboratory performance. News Street of the Association of Clinical Biochemists1991; 338: 14–17.
44.
WestwoodABullockDGWhiteheadTP. An examination of the hexokinase method for serum glucose using external quality assessment data. Ann Clin Biochem1986; 23: 92–6.
45.
SpencerK.Analytical reviews in clinical biochemistry: The estimation of creatinine. Ann Clin Biochem1986; 23: 1–25.
46.
National Committee for Clinical Laboratory Standards (NCCLS). Guidelines for the Development of Definitive Methods for Use in Clinical Chemistry for the National Reference System in Clinical Chemistry; NRSCC 1. Villanova: NCCLS, 1979.
47.
CohenAHertzHSMandelJTotal serum cholesterol by isotope dilution/mass spectrometry: A candidate definitive method. Clin Chem1980; 26: 854–60.
48.
GramlichJWMachlanLABrieticKAKellyWR. Thermal-ionization isotope-dilution mass spectrometry as a definitive method for determination of potassium in serum. Clin Chem1982; 28: 1309–13.
49.
BjorkhemIBlomstrandROhmanG.Determination of serum urea by mass fragmentography. Clin Chim Acta1976; 71: 199–205.
50.
BjorkhemIBlomstrandRLanttoOSvenssonLOhmanG.Toward absolute methods in clinical chemistry: Application of mass fragmentography to high-accuracy analyses. Clin Chem1976; 22: 1789–801.
51.
NissimIYudkoffMYangWTerwilligerTSegalS.Rapid gas chromatographic-mass spectrometric analysis of [15N] urea: Application to human metabolic studies. Clin Chim Acta1981; 109: 295–304.
52.
NelsonJERuoTI. Assay of stable isotope labelled urea in biological fluids by selected ion monitoring. Clin Chim Acta1988; 175: 59–65.
53.
TserngK-YKalhamSC. Gas chromatography/mass spectrometric determination of 15N urea in plasma and application to urea metabolism study. Anal Chem1982; 54: 489–91.
54.
WelchMJCohenAHertzHSRueggFCSchafferRSniegoskiLTDetermination of serum urea by isotope dilution mass spectrometry as a candidate definitive method. Anal Chem1984; 56: 713–19.
55.
National Committee for Clinical Laboratory Standards (NCCLS). National Reference System for the Clinical Laboratory: NCCLS Document RS11-P (Urea).Villanova: NCCLS, 1986.
56.
National Committee for Clinical Laboratory Standards (NCCLS). Development of Definitive Methods for Use in Clinical Chemistry for the National Reference System in Clinical Chemistry: Tentative Guideline. NCCLS publication NRSCC1-T. Villanova: NCCLS, 1984.
57.
TalkeHShubertGA. Enzymatische Harnstoffbestimmung in Blut und Serum in optischen test nach Warburg. Klin Wochenschr1965; 43: 174–6.
58.
National Committee for Clinical Laboratory Standards. Development of Reference Methods in Clinical Chemistry for the National Reference System in Clinical Chemistry: Tentative Guideline. NCCLS Publication NRSCC2-T. Villanova: NCCLS, 1984.
59.
National Bureau of Standards Certificate of Analysis. Standard Reference Material 909. Maryland; NBS, 1988.
60.
FearonWR. CX. The carbamido diacetyl reaction: A rest for citrulline. Biochem J1939; 33: 902–7.
61.
ButlerARHussainILeitchE.The chemistry of the diacetyl monoxime assay of urea in biological fluids. Clin Chim Acta1981; 112: 357–60.
62.
KoritzSBCohenPP. Colorimetric determination of carbamylamino acids and related compounds. J Biol Chem1954; 209: 145–50.
63.
OrmsbyAA. A direct colorimetric method for the determination of urea in blood and urine. J Biol Chem1942; 146: 595–604.
64.
KawerauE.The estimation of urea, citrulline, allantoin and related carbamido compounds. Sci Proc Roy Dublin Soc1946; 42: 63–70.
65.
NatelsonSScottMLBeffaC.Rapid methods for estimation of urea in biologic fluids; by means of reaction between diacetyl and urea. Am J Clin Pathol1951; 21: 275–81.
66.
FriedmanHS. Modification of the determination of urea by the diacetyl monoxime method. Anal Chem1953; 25: 662–3.
67.
MartinekRG. Review of methods for determining urea nitrogen in biologic fluids. J Am Med Technol1969; 31: 678–96.
68.
CoulombeJJFavreauLA. A new simple semimicro method for colorimetric determination of urea. Clin Chem1963; 9: 102–8.
69.
MarshWHFingerhutBMillerH.Automated and manual direct methods for the determination of blood urea. Clin Chem1965; 11: 624–7.
70.
DickenmanRCCraftsBZakB.Use of alpha diketones for analysis of urea. Am J Clin Pathol1954; 24; 981–7.
RahmtullahMBoydeTRC. Improvements in the determination of urea using diacetyl monoxime; methods with and without deproteinisation. Clin Chim Acta1980; 107: 3–9.
74.
LondonMHonyKHuberH.Rapid microanalyzer for glucose and urea. Clin Chem1976; 22: 1537–8.
75.
SmithMLittleAJPayneRB. An evaluation of the first production model of the Rank Hilger Chemispek multichannel electrolyte analyser. Ann Clin Biochem1981; 18: 15–21.
76.
LeonardJV. An assessment of the performance of the SMA12/micro autoanalyser in clinical use. Ann Clin Biochem1975; 12: 70–7.
77.
JungDBiggsHEriksonJLedyardP.A new colorimetric assay for urea. Clin Chem1974; 20: 871–2.
78.
JungDBiggsHEriksonJLedyardP.New colorimetric reaction for end-point continuous-flow and kinetic measurement of urea. Clin Chem1975; 21: 1136–40.
79.
MooreheadWRBiggsHREiskampJGWaltzR.A nonenzymatic kinetic method for urea analysis on the centrifugal fast analyser. Clin Chem1975; 21: 964.
80.
LevinsonSS. Kinetic centrifugal analyser and manual determination of serum urea nitrogen with use of o-phthalaldehyde reagent. Clin Chem1978; 24: 2199–202.
81.
MomoseTMomoseT.Kinetic determination of serum urea nitrogen with o-phthalaldehyde and N-(1-naphthyl)-N′-diethylene diamine. Clin Chim Acta1981; 114: 297–301.
82.
LequangNTMigneresGRocheDPelladeauMLLabrousseF.Improved dye procedure for determining urea concentration by using o-phthalaldehyde and naphthylethylenediamine. Clin Chem1987; 33: 192.
83.
BallMJKayJDSSmithD.Interference in urea determination by high immunoglobulin levels. Ann Clin Biochem1985; 22: 215–16.
84.
WoodPLHillBHillPG. Kinetic o-phthalaldehyde method for urea eliminates errors due to interference by monoclonal proteins. Clin Chem1987; 33: 723–4.
GrossenbacherHCookAMHuetterR.Determination of biuret and urea by high-performance liquid chromatography. J Chromatogr1985; 331: 161–7.
87.
BeeuwkesRIIIAmbergJMEssandohL.Urea measurement by X-ray microanalysis in 50 picoliter specimens. Kidney Int1977; 12: 438–42.
88.
HartmannLCahourALemaitreBFihmanAMMassiasJF. Determination of urea by gas-liquid chromatography. A comparison with two other methods. Pathol Biol1979; 27: 643–6.
89.
PasteurL.Response a observations de M Berthelot sur la theories des fermentations. Paris Acad Sci Compt Rend1876; 83: 10.
90.
SumnerJB. The isolation and crystallization of the enzyme urease. J Biol Chem1926; 69: 435–41.
91.
DixonNEGazzolaCWattersJJBlakeleyRLZernerB.Jack bean urease (EC 3.5.1.5) A metalloenzyme. A simple biological role for nickel?J Am Chem Soc1975; 97: 4130–3.
92.
DixonNEGazzolaCAsherCJLeeDSWBlakeleyRLZernerB.Jack bean urease (EC 3.5.1.5). II. The relationship between nickel enzymatic activity and the ‘abnormal’ ultraviolet spectrum. The nickel content of jack beans. Can J Biochem1980; 58: 474–80.
93.
AndrewsRKBlakeleyRLZernerB.Urea and urease. Adv Inorg Biochem1984; 6: 245–83.
94.
BlakeleyRLHindsJAKunzeHEWebbECZernerB.Jack bean urease (EC 3.5.1.5). Demonstration of a carbamoyl-transfer reaction and inhibition by hydroxamic acids. Biochemistry1969; 8: 1991–2000.
95.
BlakeleyRLWebbECZernerB.Jack bean urease (EC 3.5.1.5). A new purification and reliable rate assay. Biochemistry1969; 8: 1984–90.
96.
DixonNEHindsJAFihellyAKJack bean urease (EC 3.5.1.5). IV. The molecular size and mechanism of inhibition by hydroxamic acids, spectrophotometric titration of enzymes with reversible inhibitors. Can J Biochem1980; 58: 1323–34.
97.
RiddlesPWAndrewsRKBlakeleyRLZernerB.Jack bean urease VI. Determination of thiol and disulfide content. A reversible inactivation of the enzyme by the blocking of the unique cysteine residue. Biochim Biophys Acta1983; 743: 115–20.
98.
Van SlykeDDCullenGE. The mode of action of urease and of enzymes in general. J Biol Chem1914; 19: 141–80.
99.
Van SlykeDDZachariasG.The effect of hydrogen ion concentration and of inhibiting substances of urease; further study on the mode of enzyme action. J Biol Chem1914; 19: 181–210.
100.
HowellSFSumnerJB. The specific effects of buffers upon urease activity. J Biol Chem1934; 104: 619–26.
101.
VarleyHGowelockAHBellM.Non-protein nitrogen, urea, creatine and creatinine. In: Practical Clinical Biochemistry, 5th edn, Vol I: General topics and commoner tests. London: Heinemann, 1980; 451–88.
102.
FasmanGDNiemannC.A re-investigation of the kinetics of the urease-catalysed hydrolysis of urea. I. The activity of urease in the presence of sodium and potassium phosphate. J Am Chem Soc1951; 73: 1646–50.
103.
WallMCLaidlerKJ. The molecular kinetics of the urea-urease system. IV. The reaction in an inert buffer. Arch Biochem Biophys1953; 43: 299–306.
HornDBSquireCR. An improved method for the estimation of ammonia in blood plasma. Clin Chim Acta1967; 17: 99–105.
107.
WeichselbaumTEHagertyJCMarkHB.JrA reaction rate method for ammonia and blood urea nitrogen using pentacyanonitrosyloferrate catalysed Berthelot reaction. Anal Chem1969; 41: 848.
108.
ChaneyALMarbachEP. Modified reagents for determination of urea and ammonia. Clin Chem1962; 8: 130–2.
109.
FawcettJKScottJE. A rapid and precise method for the determination of urea. J Clin Pathol1960; 13: 156–9.
110.
NapierJAFLinesJG. Emergency determination of urea. Ann Clin Biochem1969; 659–64.
111.
ShullBChenyC-SRahillWJ. Effect of haemolysis on values obtained for urea nitrogen in plasma. Clin Chem1973; 19: 1226.
112.
SearcyRLReardonJForemanJA. A new photometric method for serum urea nitrogen determination. Am J Med Technol1967; 33: 15–20.
113.
GordonSAFleckABellJ.Optimal conditions for the estimation of ammonium by the Berthelot reaction. Ann Clin Biochem1978; 15: 270–5.
114.
NaftalinLWhittakerJFStephensA.A quick specific and sensitive method, based on the ultramicro determination of ammonia-N, for estimating blood urea. Clin Chim Acta1966; 14: 771–6.
115.
GlebkoLIUlkinaJIVaskovskyVE. Spectrophotometrical method for determination of nitrogen in biological preparations based on thymol-hypobromite reaction. Anal Biochem1967; 20: 16–23.
116.
Keler-BacokaMKosBStojanovski-BubanjA.Comparison and statistical evaluation of blood urea results determined by the hypobromite urease-hypochlorite and urease-microdiffusion methods. Acta Med Iugosl1972; 26: 433–8.
117.
ChirilloRCaenaroGPavanBPinA.The use of immobilised enzyme reactors in continuous-flow analysers for the determination of glucose urea and uric acid. Clin Chem1979; 25: 1744–8.
118.
CollissJSKnoxJM. The use of immobilised urease for the determination of plasma urea by continuous flow analysis. Med Lab Sci1978; 35: 275–82.
119.
SundaramPVIgloiMPWassermannRHinschWKnokeKJ. Immobilised-enzyme nylon-tube reactors for routine determination of urea and citrulline in serum. Clin Chem1978; 24: 234–9.
YugariYYMinamotoYKomiyaKMitsugiKMimuraN.Immobilisation of enzyme on PMG and its application to the urea monitoring apparatus. Enzyme Eng1978; 4: 223–5.
SeniorPJCollinsSH. Urea assay mixture. Eur Pat Appl EP82-303157, UK; Imperial Chemical Industries PLC, 1983.
124.
Roch-RamelF.An enzymic and fluorophotometric method for estimating urea concentrations in nanoliter specimens. Anal Biochem1967; 21: 372–81.
125.
Du Pont Instruments. Du Pont ACA (Automatic Clinical Analyser) Methods, BUN-Urea Nitrogen (700A2).Delaware: DuPont de Nemours and Co. Inc., 1968.
126.
BretaudiereJPHungTPBaillyM.Direct enzymic determination of urea in plasma and urine with a centrifugal analyser. Clin Chem1976; 22: 1614–17.
127.
Sigma Chemical Company. Sigma Urea Nitrogen Diagnostic Kit No 66-UV.Poole, UK: Sigma Chemical Co Ltd.
128.
DowdDKochDWiebeDFeldbrueggeD.Development of a rate BUN method for use on the Hitachi 737. Clin Chem1987; 33: 1010.
129.
HolzbergRASommerMMoskalskiWBFritscheET. A modified enzymatic approach used to measure blood urea nitrogen on the Technicon RA1000 system. Clin Chem1989; 35: 1104.
130.
SampsonEJBairdMA. Chemical inhibition used in kinetic urease/glutamate dehydrogenase method for urea in serum. Clin Chem1979; 25: 1721–9.
131.
OrsonneauJLMeflahKLustenbergerPCornuGBernardS.Sensitisation and visualisation of biochemical measurements using the NAD/NADH system by means of Meldola blue II. Application to the continuous flow determination of plasma glucose and urea. Clin Chim Acta1982; 125: 185–92.
132.
YostDACooperCBaugherW.An assay to measure blood urea nitrogen on the Abbot TDx analyser. Clin Chem1985; 31: 970.
133.
LespinasFDupuyGRevolFAubryC.Enzymic urea assay: A new colorimetric method based on hydrogen peroxide measurement. Clin Chem1989; 35: 654–8.
134.
TrinderP.Determination of glucose in blood using glucose oxidase with an alternative oxygen acceptor. Ann Clin Biochem1969; 6: 24–7.
135.
HeinonenTRaunioRLaviJLovgrenTKurkijarviK.Measurement of glutamate ammonia and urea with bacterial bioluminescence. In: KrickaLJ, ed. Proceedings of the 3rd International Symposium on Analytical Applications of Bioluminescence and Chemiluminescence. London: Academic Press, 1984; 325–8.
136.
TabataMMurachiT.A chemiluminometric method for the determination of urea in serum using a three-enzyme bioreactor. J Biolumin Chemilumin1988; 2: 63–7.
FraserCGFudgeAN. Comparison of three kits for enzymatic determination of urea. Ann Clin Biochem1978; 15: 265–9.
139.
PasseyRBGilliumRLFullerJB. Evaluation of three methods for the measurement of urea nitrogen in serum as used on six instruments. Am J Clin Pathol1980; 73: 362–8.
140.
ChinWTKroontjeW.Conductivity method for determination of urea. Anal Chem1961; 33: 1757–60.
141.
BourrellyPBourelly-DurandV.Methode d'etude per conductometric differentialle de la cinetique de l'hydrolyse enzymatique de l'uree. J Chim Phys1965; 62: 673–7.
142.
HanssMReyA.Application de la conductometrie a l'etude des reactions enzymatiques, systeme urea-urease. Biochim Biophys Acta1971; 227: 630–8.
143.
AcordWFeldmanFJ. Design considerations for a fully automated rate electrochemical glucose and urea nitrogen analyser. Clin Chem1974; 20: 903.
144.
TagamiSMatsubaASawadaTNakanoTShihoD.Chemical analysis by the measurement of reaction rates II. Conductivity method for the determination of urea using urease. Yakugaku Zasshi1974; 94: 1384–8.
145.
PaulsonGRayRSternbergJ.A rate-sensing approach to urea measurement. Clin Chem1971; 17: 644.
146.
TaylorDNiemanTA. Bipolar pulse conductimetric detection of enzyme reactions in flow-injection systems. Urea in serum and urine. Anal Chim Acta1986; 186: 91–100.
147.
MacholanLFillipekJAndrysC.Assays of urea and arginase with a biocatalytic membrane electrode operating on conductimetric principle. Acta Biotechnol1989; 9: 369–77.
148.
HeickHMCMohammedABegin-HeickN.The use of the Beckman BUN Analyser to determine the urea concentration in whole blood. Clin Biochem1981; 14: 102–3.
149.
DyerTFCocksDA. An economical reagent for use with the Beckman Analyser in estimating plasma urea. Ann Clin Biochem1980; 17: 214–5.
WatsonBKeyesMH. A dedicated instrument for the analysis of blood urea nitrogen using an immobilized enzyme reagent. Anal Lett1976; 9: 713–25.
152.
PalleschiGMasciniMMartinez-FabregasEAlegretS.Urea determination in human sera with an ammonium ion selective electrode made with solid inner electric contact and immobilized urease. Anal Lett1988; 21: 1115–29.
153.
HirschCYuGDubinskyE.Evaluation of the Nova 12 urea electrode. Clin Chem1989; 35: 100.
154.
HansonDJBretzNS. Evaluation of a semi-automated blood urea nitrogen analyser. Clin Chem1977; 23: 477–84.
155.
DemkoPRWelchRBellinoLGribenDYoungCGWinarteH.Simultaneous determination of urea, glucose, sodium, potassium, chloride and total carbon dioxide in undiluted human serum using an electrode based automated analyzer. Clin Chem1989; 35: 1091.
156.
FleisherMFlatowBSchwartzMK. Evaluation of the Nova 12: A whole blood and serum electrolyte, glucose and BUN analyser. Clin Chem1989; 35: 1128.
157.
HansenEHRuzickaJ.Enzymic analysis by means of the air gap electrode determination of urea in blood. Anal Chim Acta1974; 72: 353–64.
158.
WinquistFSpetzALundstroemIDanielssonB.Determination of urea with an ammonium gas-sensitive semiconductor device in combination with urease. Anal Chim Acta1984; 163: 143–9.
159.
GeorgesJ.Determination of ammonium and urea in urine and of urea in blood by use of an ammonia-selective electrode. Clin Chem1979; 25: 1888–90.
160.
Thanei-WyssUMorfWELienemannPDetermination of urea in 10 μl blood samples with a urease reactor/ion-selective electrode cell. Mikrochim Acta1983; 3: 135–47.
161.
BermanEMYaoSJWolfsonSKJrTokarskyJM. Enzymic-potentiometric determination of urea in human serum. Bioelectrochem Bioenerg1978; 5: 63–6.
162.
HavasJRohonczy-BoksayEPorjeszE.Urea selective enzyme probe and its analytical/clinical application. In: PungorE, ed. Bioelectroanalysis 1st Symposium.Budapest: Akad Kiado, 1987; 225–38.
163.
IhnGSWooSTSohnMJBuckRP. Preparation of the Proteus Mirabilis bacterial electrode for the determination of urea and its clinical applications. Anal Lett1989; 22: 1–13.
164.
RuzickaJHansenEHGhoseAKMottolaHA. Enzymic determination of urea in serum based on pH measurement with the flow injection method. Anal Chem1979; 51: 119–203.
165.
SzuminskyNJChenAKLiuCC. A miniature palladium-palladium oxide enzyme electrode for urea determination. Biotechnol Bioeng1984; 26: 642–5.
166.
VadgamaPMAlbertiKGMMCovingtonK.Determination of urea in blood plasma by enzyme-pH electrode. Anal Chim Acta1982; 136: 403–6.
167.
HamannHKuehnMBoettcherNSchellerF.Enzyme sensor system for potentiometric urea determination in serum and milk. J Electroanal Chem Interfacial Electrochem1986; 209: 69–76.
168.
RipamontiMMoscaARovidaEUrea, creatinine and glucose determined in plasma and whole blood by a differential pH technique. Clin Chem1984; 30: 556–9.
169.
LuzzanaMDossiGMoscaAMeasurement of glucose in plasma by a differential pH technique. Clin Chem1983; 29: 80–5.
170.
AnzaiJTezukaSOsaTNakajimaHMatsuoT.Urea sensor based on an ion-sensitive field effect transistor. IV. Determination of urea in human blood. Chem Pharm Bull1987; 35: 693–8.
171.
BonucchiDCastellaniAOrlandiniGCRipamontiMLuzzanaMMoscaA.Urea determination in dialysis based on a differential pH technique. Int J Artif Organs1987; 10: 352–6.
172.
BowersLDCanningLMJrSayersCNCarrPOW. Rapid-flow enthalpimetric determination of urea in serum with use of an immobilized urease reactor. Clin Chem1976; 22: 1314–18.
173.
BorrebaeckCBoerjesonJ.A simple routine assay for using immobilized urease. Scand J Clin Lab Invest1980; 40: 169–72.
174.
RomanRJBonventreJVLecheneCP. Fluorometric assay for urea in urine, plasma and tubular fluid. Anal Biochem1979; 98: 136–41.
175.
UchiyamaSTohfukuYSuzukiSMutoG.Determination of urea by ion chromatography with an immobilised urease reactor. Anal Chim Acta1985; 174: 313–16.
176.
JansenHvan der VeldeEGBrinkmanUATFreiRW. Liquid chromatographic determination of urea and ammonia in body fluids using a post-column enzymic reactor. J Chromatogr1986; 378: 215–21.
177.
SteinhausenRLPriceCP. Principles and practice of dry chemistry systems. In: PriceCPAlbertiKGMM, eds. Recent Advances in Clinical Biochemistry, No. 3. Edinburgh: Churchill Livingstone, 1985; 273–96.
178.
PriceCPKollerPU. A multicentre study of the new Reflotron System for the measurement of urea, glucose, triacylglycerols, cholesterol, γ-glutamyl-transferase and hemoglobin. J Clin Chem Clin Biochem1988; 26: 233–50.
179.
ClarkPMKrickaLJWhiteheadTP. Evaluation of the Kodak Ektachem glucose and urea methods. Ann Clin Biochem1980; 17: 293–300.
180.
StevensJFNewallRG. Application of reflectance spectroscopy to the estimation of uric acid, urea and glucose: An evaluation of the Ames Seralyzer. J Clin Pathol1983; 36: 9–13.
181.
ThomasLPlischkeWStorzG.Evaluation of a quantitative solid phase reagent system for determination of blood analytes. Ann Clin Biochem1982; 19: 214–23.
OrrellJMPettigrewARDominiczakMH. Accuracy of Ektachem DT system for urea improved by using 70 g/L albumin solution as diluent. Clin Chem1987; 33: 1078.
184.
HammondBRLesterE.Evaluation of a reflectance photometric method for determination of urea in blood plasma or serum. Clin Chem1984; 30: 596–7.
185.
GregoryJLesterE.Drug interference with reagent strip method for measuring urea. Lancet1982; ii: 443.
186.
HeickHMCMohammedAMurzelloLBegin-HeickN.Use of Beckman BUN Analysers to determine urea. Clin Biochem1979; 12: 104–6.
187.
FesusPDPressacMBraconnierFAymardP.Automated determination of urinary sodium, potassium, chloride, inorganic phosphate, urea and creatinine without sample dilution with the RA-XT. Clin Chem1989; 35: 481–3.
188.
EckfeldtJLevineASGreinerCKershawM.Urinary urea: Are currently available methods adequate for revival of an almost abandoned test?Clin Chem1982; 28: 1500–2.
189.
BurgessEJFleckA.Inadequacy of urinary urea for the estimation of nitrogen balance during total parenteral nutrition. Ann Clin Biochem1990; 27: 163–4.
190.
Marik-KordaP.The determination of urea and other nitrogen compounds in urine by the DIE method. J Therm Anal1982; 23: 93–9.
191.
NagashimaKSuzukiS.The determination of urea by using an enzyme reactor and second derivative spectrophotometry. Anal Chim Acta1983; 151: 13–8.
192.
AkaiTNakaKYoshikawaCSalivary urea nitrogen as an index to renal function: A test-strip method. Clin Chem1983; 29: 1825–7.
193.
SeinKTArumainayagamG.Correlation between serum urea and salivary urea. Clin Chem1987; 33: 2303.
194.
PlumbeRMWorthHGJ. Dried blood spot estimation of urea. Ann Clin Biochem1985; 22: 408–11.