In this work, we present a method for analyzing positron emission tomography (PET) functional mapping experiments. The method is useful for identifying statistically significant differences between two PET data sets. First, uniform-variance Z-images are created and then the statistical uncertainty in region-of-interest values are calculated using a previously published method. The Z-images are calculated from the emission sinograms only
BevingtonPR, (1969) Data Reduction and Error Analysis for the Physical Sciences. New York, McGraw-Hill, p 33
2.
CherrySRWoodsRPHuangS-CMazziottaJC, (1993a) Activation mapping from projection data. In: Quantification of Brain Function. Tracer Kinetics and Image Analysis in Brain PET (UemuraKLassenNAJonesTKannoT, eds.) Amsterdam, Elsevier, pp 331–337
3.
CherrySRWoodsRPHoffmanEJMazziottaJC, (1993b) Improved detection of focal cerebral blood flow changes using three-dimensional positron emission tomography. J Cereb Blood Flow Metab13:630–638
4.
DefriseMTownsendDWClackR, (1989) Three-dimensional image reconstruction from complete projections. Phys Med Biol34:573–587
5.
FoxPTMintunMA, (1989) Noninvasive functional brain mapping by change-distribution analysis of averaged PET images of H215O tissue activity. J Nucl Med30:141–149
6.
FoxPTMintunMAReimanEMRaichleME, (1988) Enhanced detection of focal brain responses using intersubject averaging and change-distribution analysis of subtracted images. J Cereb Blood Flow Metab8:642–653
7.
FristonKJFrithCDLiddlePFDolanRJLammertsmaAAFrackowiakRSJ, (1990) The relationship between global and local changes in PET scans. J Cereb Blood Flow Metab10:458–466
8.
FristonKJFrithCDLiddlePFFrackowiakRSJ, (1991) Comparing functional (PET) images: The assessment of significant change. J Cereb Blood Flow Metab11:690–699
9.
HuesmanRH, (1984) A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography. Phys Med Biol29:543–552
10.
KakACSlaneyM, (1988) Principles of Computerized Tomographic Imaging. New York, IEEE Press, pp 49–74
11.
MeikleSRDahlbomMCherrySR, (1993) Attenuation correction using count-limited transmission data in positron emission tomography. J Nucl Med34:143–144
12.
PelizzariCAChenGTYSpelbringDRWeichselbaumRRChenCT, (1989) Accurate three-dimensional registration of CT, PET, and/or MR images of the brain. J Comput Assist Tomogr13:20–26
13.
PolineJ-BMazoyerBM, (1993) Analysis of individual positron emission tomography activation maps by detection of high signal-to-noise-ratio voxel clusters. J Cereb Blood Flow Metab13:425–437
14.
TurkingtonTGJaszczakRJPelizzariCAHarrisCCMacFallJRHoffmanJMColemanRE, (1993) Accuracy of registration of PET, SPECT and MR images of a brain phantom. J Nucl Med34:1587–1594
15.
WorsleyKJEvansACMarrettSNeelinP, (1992) A three-dimensional statistical analysis for CBF activation studies in human brain. J Cereb Blood Flow Metab12:900–918