Lipid-dependent
Research article
Isolation of Malassezia species from healthy cats and cats with otitis
Simona Nardoni, Francesca Mancianti, Antonello Rum , [...]
View All
Abstract
Select search scope: search across all journals or within the current journal
Lipid-dependent
Indirect blood pressure measurements were compared in 28 conscious cats using Doppler and oscillometric blood pressure-measuring devices. Ten cats were used to compare Doppler measurements between two examiners and 18 cats were used to compare Doppler and oscillometric measurements. The Doppler machine obtained systolic and diastolic blood pressure readings in 100% and 51% of attempts, respectively. With the oscillometric machine, systolic and diastolic blood pressure readings were obtained in 52% of the attempts. With the Doppler, measures of mean systolic blood pressure between two examiners were positively correlated, but there was no correlation for diastolic blood pressure measures. When comparing the results obtained by Doppler and oscillometric machines there was no significant difference between mean systolic blood pressure readings, but the oscillometric machine produced significantly higher estimates of diastolic blood pressure. In both cases, the standard deviations for the oscillometric machine were considerably larger than those for the Doppler machine. The first reading of systolic blood pressure obtained with the Doppler machine was an excellent predictor of the mean of five readings, but this was not so for the oscillometric machine. It took less than 5 min to obtain five readings in 37.5% of cases with the Doppler machine but this was true for only 5% of cases with the oscillometric machine. Two cats with ophthalmological lesions consistent with systemic hypertension were identified. In these two patients, systolic blood pressure measurements were between 200 and 225 mmHg when measured by Doppler, and between 140 and 150 mmHg when measured by the oscillometric machine. This suggests that a lower reference range for normal systolic blood pressure values should be used for the oscillometric device.
A continuous glucose monitoring system (CGMS) was evaluated in 14 cats with naturally occurring diabetes mellitus. The device measures interstitial fluid glucose continuously, by means of a sensor placed in the subcutaneous tissue. All cats tolerated the device well and a trace was obtained on 15/16 occasions. There was good correlation between the CGMS values and blood glucose concentration measured using a glucometer (
Home-monitoring of blood glucose concentrations has recently been introduced to owners. The objectives of this study were to investigate the feasibility of home-monitoring of blood glucose in diabetic cats by owners, the problems encountered and to compare glucose concentrations at home with those measured in the hospital. Twelve of 15 cat owners were able to generate glucose curves over the study period of 4 months. Most problems were related to restraining the cat, generating negative pressure with the lancing device and producing a blood drop. In the majority of cases, these problems could be resolved during the study. Blood glucose concentrations in the clinic tended to be lower than at home; some of the differences were significant. No association between tolerance of the procedure and blood glucose concentrations measured at home was found. We, therefore, assume that the lower glucose levels in the hospital were caused by lack of food intake. In 38% of cases, treatment based on hospital curves would have been different from that based on home curves. Home-monitoring appears to be a valuable tool in the management of cats with diabetes mellitus. One of its major advantages is that it enables frequent generation of blood glucose curves, which is of particular importance in cats that are difficult to regulate.
Thirteen cases of feline primary hyperaldosteronism were diagnosed based on clinical signs, serum biochemistry, plasma aldosterone concentration, adrenal imaging and histopathology of adrenal tissue. Two cases presented with blindness caused by systemic hypertension, whilst the remaining 11 cases showed weakness resulting from hypokalaemic polymyopathy. Elevated concentrations of plasma aldosterone and adrenocortical neoplasia were documented in all cases. Seven cases had adrenal adenomas (unilateral in five and bilateral in two) and six had unilateral adrenal carcinomas. Three cases underwent medical treatment only with amlodipine, spironolactone and potassium gluconate; two cases survived for 304 and 984 days until they were euthanased because of chronic renal failure, whilst the third case was euthanased at 50 days following failure of the owner to medicate the cat. Ten cases underwent surgical adrenalectomy following a successful stabilisation period on medical management. Five cases remain alive at the time of writing with follow-up periods of between 240 and 1803 days. Three cases were euthanased during or immediately following surgery because of surgical-induced haemorrhage. One cat was euthanased 14 days after surgery because of generalised sepsis, whilst the remaining cat was euthanased 1045 days after surgery because of anorexia and the development of a cranial abdominal mass. It is recommended that primary hyperaldosteronism should be considered as a differential diagnosis in middle-aged and older cats with hypokalaemic polymyopathy and/or systemic hypertension and should no longer be considered a rare condition.
The objective of this study was to compare simpler indices of insulin sensitivity with the minimal model-derived insulin sensitivity index to identify a simple and reliable alternative method for assessing insulin sensitivity in cats. In addition, we aimed to determine whether this simpler measure or measures showed consistency of association across differing body weights and glucose tolerance levels. Data from glucose tolerance and insulin sensitivity tests performed in 32 cats with varying body weights (underweight to obese), including seven cats with impaired glucose tolerance, were used to assess the relationship between Bergman's minimal model-derived insulin sensitivity index (
To investigate heart rate and its variability, a telemetry device was affixed to 16 healthy, young cats. Prior to inclusion in the study, cats were subject to echocardiographic examination. The heart rate (HR) when cats were restrained for echocardiography (HRr) was calculated from 4–5 consecutive RR intervals obtained from a simultaneously recorded electrocardiogram. Electrocardiographic data were then acquired by telemetry in a quiet room in the veterinary hospital (VTH) and later, in the owner's home (home). The ambulatory data were digitally sampled and the RR interval tachogram from a 4 min epoch subject to Fast Fourier Transform to yield measures of heart rate variability (HRV). Sinus arrhythmia was often observed in resting cats. Heart rates (bpm) expressed as mean (±SD) were: HRr: 187 (±25), HRVTH: 150 (±23), HRhome: 132 (±19); each of these rates was significantly different from the others. Significant differences in profiles of HRV suggested that sympathetic tone was higher (and parasympathetic tone lower) when cats were in the hospital.
Clinical toxoplasmosis is commonly reported in the cat, with the most consistent findings being ocular, pulmonic, hepatic, neurological, gastrointestinal and muscular abnormalities. Myocarditis, whilst frequently identified at post-mortem examination, has not been identified ante-mortem.
In immunocompromised humans, myocarditis associated with toxoplasmosis is not an uncommon complication. In such cases, lymphocytic myocardial infiltration can lead to depressed myocardial function, which can be associated with congestive heart failure, rhythm disturbances and pericardial effusions. In addition, myocardial failure has been reported in immunocompetent humans associated with active toxoplasmosis [Chandenier J, Jarry G, Nassif D, Douadi Y, Paris L, Thulliez P, Bourges-Petit E, Raccurt C (2000) Congestive heart failure and myocarditis after seroconversion for toxoplasmosis in two immunocompetent patients. European Journal of Clinical Microbiological Infectious Disease 19, 375–379]. Here we describe a cat with echocardiographic changes consistent with infiltrative or inflammatory disease, and elevated IgG and IgM titres to





