Abstract
BACKGROUND:
Wrist-Worn Activity Monitors (WWAMs) are low-cost, user-friendly devices which have become popular for monitoring physical activity. Their reliability and validity need investigation for accurate physical activity monitoring. We examined between-sessions and inter-device reliability of the WWAMs. In addition, we examined the criteria-related validity of the WWAMs against two gold standards, an Ankle-Worn Activity monitor (AWAM) and video.
METHODS:
Twenty volunteers participated in two sessions, one week apart. In each session, participants walked on a treadmill for five minutes at each of the three speeds: 0.89 m/s (slow),1.12 m/s (moderate) and 1.33 m/s (fast). Total step counts at each speed were obtained using one AWAM (stepWatch), three-WWAMs (Fitbit Flex) and video. The Intraclass Correlation Coefficient (ICC) was calculated to determine the reliability and validity of the WWAMs.
RESULTS:
The WWAMs exhibited moderate to excellent between-sessions reliability (ICC = 0.69–0.90). The WWAMs demonstrated excellent inter-device reliability at each speed across both sessions (ICC = 0.91–0.98). The criteria-related validity of WWAMs compared to the AWAM, and video recording showed moderate to excellent agreement (ICC = 0.67–0.85) at each speed.
CONCLUSIONS:
WWAMs recorded steps consistently between-sessions and between-devices for treadmill walking among healthy adults at each speed but exhibited limited agreement for recording steps at each speed compared to AWAM and video.
Get full access to this article