Restricted accessResearch articleFirst published online 2015-11
A new,low cost,locking plate for the long-term fixation of a critical size bone defect in the ratfemur: In vivo performance,biomechanical and finite element analysis
BACKGROUND: The optimum fixation device for the critical size bone defect is not established yet.
OBJECTIVE: A reliable, feasible and low-cost fixation device for the long-term maintenance of a critical bone defect.
METHODS: A custom-made plate made of poly-methyl-methacrylate was used for the fixation of a critical defect of rats’ femurs. The screws were securely fixing both on the plate and the bone. A three point bending test, aimed to resemble the in vivo loading pattern, a Finite Element Analysis and a 24-week in vivo monitoring of the integrity of the plate fixation were utilized.
RESULTS: The plate has linear and reproducible behavior. It presents no discontinuities in the stress field of the fixation. Its properties are attributed to the material and the locking principle. It fails beyond the level of magnitude of the normal ambulatory loads. In vivo, 100% of the plates maintained the bone defect intact up to 12 weeks and 85% of them at 24 weeks.
CONCLUSION: This novel locking plate shows optimal biomechanical performance and reliability with high long-term in vivo survival rate. It is fully implantable, inexpensive and easily manufactured. It can be qualified for long term critical defect fixation in bone regeneration studies.
ReichertJ.C.SaifzadehS.WullschlegerM.E.EpariD.R.SchützM.A.DudaG.N.et al., The challenge of establishing preclinical models for segmental bone defect research, Biomaterials30(12) (2009), 2149–2163.
2.
PuelacherW.C.VacantiJ.P.FerraroN.E.SchlooB. and VacantiC.A., Femoral shaft reconstruction using tissue-engineered growth of bone, Int. J. Oral Maxillofac. Surg.25(3) (1996), 223–228.
3.
MuschlerG.F.LaneJ.M. and WernzJ., Segmental femoral defect model in the rat, in: Bone TransplantationAebiM. and RegazzoniP., eds, Springer, Berlin, 1989, pp. 167–169.
4.
YaskoA.W.LaneJ.M.FellingerE.RosenV.WozneyJ.M. and WangE.A., The healing of segmental bone defects, induced by recombinant human bone morphogenetic protein (rhBMP-2), J. Bone Joint Surg. Am.74(5) (1992), 659–671.
5.
JägerM.SagerM.Lensing-HöhnS. and KrauspeR., The critical size bony defect in a small animal for bone healing studies (II): Implant evolution and surgical technique on a rat’s femur, Biomed. Tech. (Berl.)50(5) (2005), 137–142.
6.
JohnsonK.D.AugustA.SciadiniM.F. and SmithC., Evaluation of ground cortical autograft as a bone graft material in a new canine bilateral segmental long bone defect model, J. Orthop. Trauma10(1) (1996), 28–36.
7.
SroujiS.BlumenfeldI.RachmielA. and LivneE., Bone defect repair in rat tibia by TGF-β1 and IGF-1 released from hydrogel scaffold, Cell Tissue Bank.5(4) (2004), 223–230.
8.
EinhornT.A.LaneJ.M.BursteinA.H.KopmanC.R. and VigoritaV.J., The healing of segmental bone defects induced by demineralized bone matrix. A radiographic and biomechanical study, J. Bone Joint Surg. Am.66(2) (1984), 274–279.
9.
JägerM.SagerM.Lensing-HöhnS. and KrauspeR., The critical size bony defect in a small animal for bone healing studies (I): Comparative anatomical study on rats femur, Biomed. Tech. (Berl.)50(4) (2005), 107–110.
10.
DrosseI.VolkmerE.SeitzS.SeitzH.PenzkoferR.ZahnK.et al., Validation of a femoral critical size defect model for orthotopic evaluation of bone healing: A biomechanical, veterinary and trauma surgical perspective, Tissue Eng. Part C Methods14(1) (2008), 79–88.
11.
OestM.E.DupontK.M.KongH.J.MooneyD.J. and GuldbergR.E., Quantitative assessment of scaffold and growth factor-mediated repair of critically sized bone defects, J. Orthop. Res.25(7) (2007), 941–950.
12.
ZhaoZ.YangD.MaX.ZhaoH.NieC. and SuccessfulS.Z., Repair of a critical-sized bone defect in the rat femur with a newly developed external fixator, Tohoku J. Exp. Med.219(2) (2009), 115–120.
13.
WildemannB.BamdadP.HolmerC.HaasN.P.RaschkeM. and SchmidmaierG., Local delivery of growth factors from coated titanium plates increases osteotomy healing in rats, Bone34(5) (2004), 862–868.
14.
WingerterS.CalvertG.TucciM.TsaoA.RussellG. and BenghuzziH., Comparison of two different fixation techniques for a segmental defect in a rat femur model, J. Invest. Surg.20(3) (2007), 149–155.
15.
RussellG.TucciM.ConflittiJ.GravesM.WingerterS.WoodallJ.Jr.et al., Characterization of a femoral segmental nonunion model in laboratory rats: Report of a novel surgical technique, J. Invest. Surg.20(4) (2007), 249–255.
16.
KasparK.MatziolisG.StrubeP.SentürkU.DormannS.BailH.J.et al., A new animal model for bone atrophic nonunion: Fixation by external fixator, J. Orthop. Res.26(12) (2008), 1649–1655.
17.
GlattV.EvansC.H. and MatthysR., Design, characterisation and in vivo testing of a new, adjustable stiffness, external fixator for the rat femur, Eur. Cell Mater.21 (2012), 289–298.
18.
ShaM.GuoZ.FuJ.LiJ.YuanC.F.ShiL.et al., The effects of nail rigidity on fracture healing in rats with osteoporosis, Acta Orthop.80(1) (2009), 135–138.
19.
SciadiniM.F.DawsonJ.M. and JohnsonK.D., Bovine-derived bone protein as a bone graft substitute in a canine segmental defect model, J. Orthop. Trauma11(7) (1997), 496–508.
20.
TiedemanJ.J.ConnollyJ.F.StratesB.S. and LippielloL., Treatment of nonunion by percutaneous injection of bone marrow and demineralised bone matrix. An experimental study in dogs, Clin. Orthop. Relat. Res.268 (1991), 294–302.
21.
WehnerT.WolframU.HenzlerT.NiemeyerF.ClaesL. and SimonU., Internal forces and moments in the femur of the rat during gait, J. Biomech.43(13) (2010), 2473–2479.
22.
BoerckelJ.D.DupontK.M.KolambkarY.M.LinA.S. and GuldbergR.E., In vivo model for evaluating the effects of mechanical stimulation on tissue-engineered bone repair, J. Biomech. Eng.131(8) (2009), 084502.
23.
LeppänenO.SievänenH.JokihaaraJ.PajamäkiI. and JärvinenT.L.N., Three-point bending of rat femur in the mediolateral direction: Introduction and validation of a novel biomechanical testing protocol, J. Bone Miner. Res.21(8) (2006), 1231–1237.
24.
BrzoskaN.M.MajewskaK. and Moniuszko-JakoniukJ., Mechanical properties of femoral diaphysis and femoral neck of female rats chronically exposed to various levels of cadmium, Calcif. Tissue Int.76(4) (2005), 287–298.
25.
BrownK.M.SaundersM.M.KirschT.DonahueH.J. and ReidJ.S., Effect of COX-2-specific inhibition on fracture-healing in the rat femur, J. Bone Joint Surg. Am. A86(1) (2004), 116–123.
26.
UtvagS.E. and ReikerasO., Effects of nail rigidity on fracture healing: Strength and mineralisation in rat femoral bone, Arch. Orthop. Trauma Surg.118(1,2) (1998), 7–13.
27.
WheelerD.L.EschbachE.J.MontfortM.J.MaheshwariP. and McLoughlinS.W., Mechanical strength of fracture callus in osteopenic bone at different phases of healing, J. Orthop. Trauma14(2) (2000), 86–92.
28.
ShefelbineS.J.SimonU.ClaesL.GoldA.GabetY.BabI.MüllerR. and AugatP., Prediction of fracture callus mechanical properties using micro-CT images and voxel-based finite element analysis, Bone36(3) (2005), 480–488.
29.
MichailidisN.KarabinasG.TsouknidasA.MaliarisG.TsipasD. and KoidisP., A FEM based endosteal implant simulation to determine the effect of peri-implant bone resorption on stress induced implant failure, Bio-Med. Mater. Eng.23(5) (2013), 317–327.
30.
VicecontiM.OlsenS.NolteL.P. and BurtonK., Extracting clinically relevant data from finite element simulations, Clin. Biomech.20(5) (2005), 451–454.
31.
TsouknidasA.SavvakisS.AsaniotisY.AnagnostidisK.LontosA. and MichailidisN., The effect of kyphoplasty parameters on the dynamic load transfer within the lumbar spine considering the response of a bio-realistic spine segment, Clin. Biomech.28(9,10) (2013), 949–955.
32.
KellerT.S. and SpenglerD.M., Regulation of bone stress and strain in the immature and mature rat femur, J. Biomech.22(11,12) (1989), 1115–1127.
33.
StürmerE.K.Seidlová-WuttkeD.SehmischS.RackT.WilleJ.FroschK.H.et al., Standardized bending and breaking test for the normal and osteoporotic metaphyseal tibias of the rat: Effect of estradiol, testosterone, and raloxifene, J. Bone Miner. Res.21(1) (2006), 89–96.
34.
HoganH.A.RuhmannS.P. and SampsonH.W., The mechanical properties of cancellous bone in the proximal tibia of ovariectomized rats, J. Bone Miner. Res.15(2) (2000), 284–292.
35.
BrzóskaM.M.MajewskaK. and Moniuszko-JakoniukJ., Bone mineral density, chemical composition and biomechanical properties of the tibia of female rats exposed to cadmium since weaning up to skeletal maturity, Food Chem. Toxicol.43(10) (2005), 1507–1519.
36.
HuangT.H.LinS.C.ChangF.L.HsiehS.S.LiuS.H. and YangR.S., Effects of different exercise modes on mineralization, structure, and biomechanical properties of growing bone, J. Appl. Physiol.95(1) (2003), 300–307.
37.
Engineering ToolBox, Elastic properties and Young modulus for some materials, 2010, available at: http://www.engineeringtoolbox.com/young-modulus-d_417.html (10/05/2014).
38.
EgolK.A.KubiakE.N.FulkersonE.KummerF.J. and KovalK.J., Biomechanics of locked plates and screws, J. Orthop. Trauma18(8) (2004), 488–493.
39.
WagnerM., General principles for the clinical use of the LCP, Injury34(Suppl. 2) (2003), B31–B42.
40.
GautierE. and SommerC., Guidelines for the clinical application of the LCP, Injury34(Suppl. 2) (2003), B63–B76.
41.
SammarcoG.J.BursteinA.H.DavisW.L. and FrankelV.H., The biomechanics of torsional fractures: The effect of loading on ultimate properties, J. Biomech.4(2) (1971), 113–117.
42.
BurayF.BourgoisP. and DonkerwolkckeM., Elastic external fixation: Concepts in external fixation. A biomechanical study of the half-frame, in: Concepts in External FixationSeligsonD. and PopeM.H., eds, Grune & Stratton, New York, 1982, p. 67.
43.
BursteinA.H.CurreyJ.FrankelV.H.HeipleK.G.LunsethP. and VesselyJ.C., Bone strength: The effect of screw holes, J. Bone Joint Surg.54(6) (1972), 1143–1156.
44.
ChaoE.Y.S. and PopeM.H., The mechanical basis of external fixation, in: Concepts in External FixationSeligsonD. and PopeM.H., eds, Grune & Stratton, New York, 1982, p. 13.