StarkNJ.Project management of medical devices trials: taking control of the
process. Clinical Device Group. July 7, 2010. http://www.clinicaldevice.com/Publications.htm. Last accessed
January 9, 2014
2.
NutleyMGuidoinRYinTDetailed analysis of a series of explanted Talent AAA
stent-grafts: biofunctionality assessment. J
Long-term Eff Med Implants.
2011;21:299–319
3.
HarrisPLVallabhaneniSRDesgrangesPIncidence and risk factors of late rupture, conversion, and death
after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR
experience. J Vasc Surg.
2000;32:739–749
BrunkwallJ.How to design the optimal stent-graft – what have we
learn?Scand J Surg.
2008;97:191–194
6.
MorrisonJWPelletierMHRivesACorrosion resistance, surface evaluation, and geometric design
comparison of five selfexpanding nitinol stents used in clinical
practice. J Endovasc Ther.
2014;21:230–239
7.
StoeckelDPeltonADuerigT.Self-expanding nitinol stents: material and design
considerations. Eur J Radiol.
2004;14:292–301
8.
TrépanierCTabrizianMYahiaLHEffect of modification of oxide layer on NiTi stent corrosion
resistance. J Biomed Mater Res.
1998;43:433–440
9.
LinJGuidoinRWangLLong-term resistance to fracture and/or corrosion of the nitinol
wires of the Talent stent-graft: observations from a series of explanted
devices. J Long-term Eff Med Implants.
2013;23:45–59
10.
O'ConnorAB.The need improved access to FDA reviews.
JAMA.
2009;302:191–193
11.
DhruraSSBeroLARedbergRF.Strength of study evidence examined by FDA in pre-market approval
of cardiovascular devices. JAMA.
2009;302:2679–2685
12.
GuidoinRDouvilleYBasléMFBiocompatibility studies of the Anaconda stent-graft and
observations of nitinol corrosion resistance. J
Endovasc Ther.
2004;11:385–403
13.
MajorAGuidoinRSoulezGImplant degradation and poor healing after endovascular repair of
abdominal aortic aneurysms: an analysis of explanted
stent-grafts. J Endovasc Ther.
2006;13:457–467
14.
NoishikiYTomizawaYYamaneYThe vicious cycle of nonhealing neointima in fabric vascular
prostheses. Artif Organs.
1995;19:7–16
15.
GuidoinRZhangZDionneGCorrosion of the nitinol wire of endovascular prostheses: does nickel
ion release impair the device performance? In: Medical
Device Materials: Proceedings From the Materials and Processes for Medical
Devices Conference August 24–27, 2004. St. Paul, MN, USA.
HelmusMMedlinD
eds. Materials Park, OH, USA: ASM
International.2005:284–289.
16.
XuZFanYGeelkerkenRMCharacterization of an endovascular prosthesis using the 3Bs rule
(biocompatibility, biofunctionality and biodurability): a recommended
protocol to investigate a device harvested at necropsy.
J Long-term Eff Med Implants.
2007;17:237–262
17.
HalwaniDOAndersonPGBrottBCClinical device related article: surface characterization of
explanted endovascular stents: evidence of in vivo
corrosion. J Biomed Mater Res (B, Appl
Biomater).
2010;95:225–238
18.
HalwaniDOAndersonPGLemonsJEIn vivo corrosion and local release of metallic ions from
vascular stents into surrounding tissue. J Invasive
Cardiol.
2010;22:525–535