Abstract
Objective:
The aim of this study is to assess the diagnostic accuracy of the spot urine protein/creatinine ratio compared with the 24-hour urine protein in pregnancy.
Study Design:
In this prospective cohort study of inpatient pregnant women, the protein/creatinine ratio and dipstick protein were assessed from a single urine sample collected at the start of the 24-hour urine. Both tests were compared with the 24-hour urine protein for correlation and test characteristics.
Results:
In the 196 specimens analysed, we found a strong correlation between the spot
urine protein/creatinine ratio and 24-hour urine protein (
Conclusion:
The spot urine protein/creatinine ratio correlated well with the 24-hour urine protein and performed better than the urine dipsticks. Significant proteinuria in pregnancy was excluded if the protein/creatinine ratio was <0.1 and identified when it was ≥0.4.
Get full access to this article
View all access options for this article.