Abstract
Background
Optimal contrast enhancement is crucial for the detection of coronary artery stenoses and atherosclerotic changes in coronary CT angiography (CTA).
Purpose
To demonstrate the feasibility of using the cardiac output (CO) obtained from the test bolus injection data-set (COtest) as a factor in contrast injection rate revision of the following coronary CTA.
Material and Methods
The test bolus injection data-sets of 52 consecutive coronary CTAs were examined. COtest was calculated from the test bolus data-set. Aortic peak enhancement (APE) was measured on the following coronary CTA. We simulated the APE at a fixed contrast injection rate of 4 mL/s (simAPE) in each patient.
Results
The ranges of COtest and simAPE were 2.82-7.56 L/min and 194-527 Hounsfield Units, respectively. There was a significant negative correlation (R = -0.802, P < 0.001) between simAPE and COtest.
Conclusion
COtest can be used for injection rate revision on coronary CTA.
Get full access to this article
View all access options for this article.