An increasingly popular method of aiding the precise placement of bonded brackets is to identify the long axis and centre of the crown with small pencil marks. A case is reported where marks placed with a soft pencil in the centre of the etched enamel have led to the inclusion of pigment deep in the enamel surface which has proved impossible to remove.
Get full access to this article
View all access options for this article.
References
1.
ArtunJ. and BrobakkenB. O. (1986) Prevalence of carious white spots after treatment with multi-bonded appliances, European Journal of Orthodontics, 8, 229–234.
2.
BisharaS. E., DenehyG. E. and GoepferdS. J. (1987) A conservative postorthodontic treatment of enamel stains, American Journal of Orthodontics and Dentofacial Orthopedics, 92, 2–7.
3.
CeenR. F. and GwinnettA. J. (1980) Indelible iatrogenic staining of enamel following debonding, Journal of Clinical Orthodontics, 14, 713–715.
4.
PusM. D. and WayD. C. (1980) Enamel loss due to orthodontic bonding with filled and unfilled resins using various clean-up techniques, American Journal of Orthodontics, 77, 269–274.
5.
SilverstoneL. M. (1975) The acid etch technique: in vitro studies with special reference to the enamel surface and the enamel-resin interface. In SilverstoneL. M. and DoganL. (eds) Proceedings of the International Symposium on the Acid Etch Technique, chapter 4, St Pauls: North Central Publishing Co.
6.
ZachrissonB. U. (1985) Bonding in orthodontics, In: GraberT. M. and SwainB. F. (eds) Orthodontics. Current Principles and Techniques, chapter 8, C. V. Mosby Co., St. Louis, Missouri.