Single tracings of cephalographs involve errors of the kind known as errors of a single measurement. An analysis of these errors has shown that they are of a high order even when cephalographs are traced by experienced orthodontists. The significance of these findings is discussed and a method of reducing errors by replication of tracings is described.
Get full access to this article
View all access options for this article.
References
1.
AdamsJ. W. (1940) Correction of error in cephalometric roentogramsAngle Orthodont., 10, 3.
2.
BacklundE. (1963) Facial growth and the significance of oral habits, mouth breathing and soft tissues for malocclusion: a study of children around the age of 10Acta. Odont. Scand.21, Suppl. 36.
3.
BaumrindS. and FrantzR. C. (1971) The reliability of head film measurements. Part 1: landmark identificationAmer. J. Orthodont., 60, 111. Part 2: conventional angular and linear measures Amer. J. Orthodont., 60, 505.
4.
BennetD. T. and SmalesF. C. (1969) Accuracy of angular measurements obtained from radiographic cephalometric analysisJ. dent. Res., 48, 595.
5.
BjörkA. (1947) The face in profileSvensk. tandläk., -T., 40, No. 5B.
6.
BroadwayE. S., HealyM. J. R. and PaytonH. G. (1962) The accuracy of tracings from cephalometric lateral skull radiographsDent. Practnr, 12, 455.
7.
CarlssonG. E. (1967) Error in X-ray cephalometryOdont. T., 75, 99.
8.
FranklinJ. B. (1952) Certain factors of aberration to be considered in clinical roentographic cephalometryAmer. J, Orthodont., 38, 351.
9.
HallettG. E. M. (1959) Inherent errors in cephalometric films and their reductionTrans. Brit. Soc. Orthodont., 163.
10.
HattonM. E. and GraingerR. M. (1958) Reliability of measurements from cephalograms at the Burlington Orthodontic Research CentreJ. dent. Res., 37, 853
11.
HixonE. H. (1956) The norm concept and cephalometricsAmer. J. Orthodont., 42, 898.
12.
KeanM. R. (1958) Some aspects of facial depth in Class II division 1 malocclusionAngle Orthodont., 28, 1.
13.
KvamE. and KrogstadO. (1969) Variability in tracings of lateral head plates for diagnostic orthodontic purposes. A methodological studyActa. Odont. Scand., 27, 359.
14.
MillsJ. R. E. (1964) The effect on the lower incisors of uncontrolled extraction of lower premolarsEurop. orthodont. Soc. Rep., page 357.
15.
MillsJ. R. E. (1966) The long-term results of the proclination of lower incisorsBrit. dent. J., 120, 355.
16.
MillerP. A., SavaraB. S. and SinghI. J. (1966) Analysis of errors in cephalometric measurement of three-dimensional distances on the maxillaAngle Orthodont., 36, 169.
17.
RichardsonA. (1966) An investigation into the reproducibility of some points, planes and lines used in cephalometric analysisAmer. J. Orthodont., 52, 637.
18.
SavaraB. S., TracyW. E. and MillerP. A. (1966) Analysis of errors in cephalometric measurements of three-dimensional distances in the human mandibleArchs oral Biol., 11, 209.
19.
ThurrowR. C. (1951) Cephalometric methods in research and private practiceAngle Orthodont., 21, 194.