Abstract
A newly developed low transformation temperature welding wire, of which the transformation start temperature is lower than that of conventional welding wires, was applied to fabrication of fillet welded T joints. The welding angular distortion and the temperature profile of the weld metal were continuously measured during the welding process. The angular distortion of the fabricated T joint was reduced when the weld metal reached the martensitic transformation start temperature. The residual angular distortion was less with the low transformation temperature welding wire than that with the conventional welding wires. The welding distortion of T joints was calculated by a numerical simulation with consideration of the effect of phase transformation under weld thermal cycles. The welding distortion was reproduced with high accuracy in the numerical simulation. Results of the numerical simulation also determined that there was a direct correspondence between the transformation expansion of the weld metal and the angular distortion.
Keywords
Get full access to this article
View all access options for this article.