Based on modeling and measurements, the authors investigated the performance of expanded polystyrene and lightweight aerated concrete slabs. The objective of the work was to assess the performance of the brick wall (having various thickness and layering) commonly built in the Silesia Region (Poland) in the 1920s and the changes of water content in layers of the flat wall through the measurement of temperature and relative humidity in the selected layers of the masonry wall.
EN 15026:2007 (2007) Hygrothermal performance of building components and building elements. Assessment of moisture transfer by numerical simulation.
2.
FechnerHHäuplPStoppHet al. (1999) Measurements and numerical simulation of the heat and moisture transfer in envelope parts of buildings. In: Proceedings 1st International Conference on Thermophysical Properties of Materials, pp.55–61. Singapore: Advanced Material Research Centre, Nanyang Technological University.
3.
GonçalvesMD (2003) Insulating solid masonry walls. In:Ninth Conference on Building Science and Technology, Vancouver, BC, 171–181. Markham, ON: Ontario Building Envelope Council.
4.
HensH (1998) Performance prediction for masonry walls with inside insulation using calculation procedures and laboratory testing. Journal of Thermal Envelope and Building Science22: 32–48.
5.
KloseikoPArumagiEKalameesT (2015) Hygrothermal performance of internally insulated brick wall in cold climate: a case study in a historical school building. Journal of Building Physics38(5): 444–464. Available at: www.testo.com.pl
6.
KünzelHM (1994) Verfahren zur ein- und zweidimensionalen Berechnung des gekoppelten Wärme- Und Feuchtetransports in Bauteilen mit einfachen Kennwerten. Dissertation, Universität Stuttgart, Stuttgart.
7.
KünzelHM (1995) Simultaneous Heat and Moisture Transport in Building Components. One- and Two-Dimensional Calculation Using Simple Parameters. Stuttgart: IRB Verlag.
8.
PN-EN ISO 13788:2013-05 (2013) Hygrothermal performance of building components and building elements—Internal surface temperature to avoid critical surface humidity and interstitial condensation—Calculation methods.
9.
RousseauMZMaurenbrecherAHP (1990) Rehabilitation of Solid Masonry Walls. Institute for research in construction, Originally published in Construction Canada32(5): 15–20. Available at: http://irc.nrc-Cnrc.gc.ca/pubs/cp/wal1_e.html
10.
SchöberlHHoferRChL (2012) Handbuch thermische Gebäudesanierung Optimale Ausführungsvarianten erstellt im Rahmen des Projekts: REBE—Regionale Zusammenarbeit und Wissenstransfer Im Bereich Bioenergie und Energieeffizienz. Wien: Landesinnung Bau Niederösterreich.
11.
StoppHStrangeldPFechnerHet al. (2016) The Hygrothermal Performance of External Walls with Inside Insulation; Buildings VIII/Wall Performance—Practices, 1–13.
12.
StraubeJFSchumacherCJ (2007) Interior insulation retrofits of load-bearing masonry walls in cold climates. Journal of Green Buildings2(2): 42–50.
13.
StraubeJFUenoKSchumacherCJ (2012) Measure Guideline: Internal Insulation of Masonry Walls. Washington, DC: U.S. Department of Energy.
14.
TrochonowiczMWitekBChwiejM (2013) Analiza wpływu wilgotności i temperatury powietrza na wartość współczynnika przewodności cieplnej materiałów termoizolacyjnych stosowanych wewnątrz pomieszczeń. Budownictwo i Architektura12(4): 165–176.
15.
WilkinsonJDe RoseDStraubeJFet al. (2009). Measuring the impact of interior insulation on solid masonry walls in a cold climate. In: Proceedings of Canadian building science & technology conference, Montreal, pp.97–110.