Abstract
Introduction
Tandem lesions involving a large vessel occlusion intracranially with concomitant cervical carotid critical stenosis or occlusion are a common presentation of acute ischemic stroke. These lesions are both challenging and time-consuming but can be extremely beneficial for patients when successful. We present a technique utilizing the pusher wire of the stent retriever used for intracranial thrombectomy as the workhorse wire for carotid intervention using a monorail system to perform cervical carotid angioplasty.
Methods
We reviewed four successive patients who presented with a tandem occlusion and underwent thrombectomy and simultaneous carotid artery intervention using this technique.
Results
All four patients had radiographically successful intracranial thrombectomy and cervical carotid revascularization. Time from groin puncture to intracranial stent retriever deployment was 63 min on average. Then, using the pusher wire as a monorail workhorse, time from stent retriever deployment to carotid angioplasty was on average 6 min.
Discussion
This technique allows for cervical carotid revascularization to begin during the recommended 5-min wait time after stent retriever deployment, allowing for rapid near-simultaneous revascularization across both lesions. This technique has been reported briefly in the past for management of a cervical dissection. There is continued debate regarding the management of tandem occlusions, as to which lesion should be managed first.
Conclusion
As the management paradigms of tandem occlusions continue to evolve, this technique may improve outcomes by expediting endovascular intervention. Using the stent retriever wire provides a method of expediting the management of the proximal lesion after addressing the more distal intracranial occlusion first.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.