The Hemodialysis Reliable Outflow (HeRO) device is a novel alternative for dialysis access in patients with no suitable veins in the upper extremities. We placed a HeRO device in a 67-year-old woman with end-stage renal disease and 2 months later, it was being used for hemodialysis. After 1 month of uneventful use, the device thrombosed and it was rescued with a percutaneous endovascular approach. The device remains patent 6 months after the intervention.
NKF-K/DOQI clinical practice guidelines and clinical practice recommendations, 2006 updates: vascular access. Am J Kidney Dis. 2006;48(suppl 1):S176-S307.
2.
Chemla ES, Morsy M., Anderson L., Makanjuola D.Complex bypasses and fisulas for difficult hemodialysis access: a prospective single-center experience. Semin Dial. 2006 ;19(3):246-250.
3.
Pierre-Paul D., Williams S., Lee T., Gahtan V.Saphenous vein loop to femoral artery arteriovenous fistula: a practical alternative. Ann Vasc Surg. 2004;18(2):223-227.
4.
Morsy MA, Khan A., Chemla ESProsthetic axillary-axillary arteriovenous straight access (necklace graft for difficult hemodialysis patients: a prospective single-center experience . J Vasc Surg. 2008;48(5):1251-1254.
5.
NKF-DOQI clinical practice guidelines for vascular access. National Kidney Foundation-Dialysis Outcomes Quality Initiative. Am J Kidney Dis. 1997;30(4 suppl 3):S150-S191.
6.
NKF-K/DOQI clinical practice guidelines for vascular access: update 2000. Am J Kidney Dis. 2001;37(1 suppl 1):S137-S181.
7.
Lacson E. Jr , Lazarus JM, Himmelfarb J., Ikizler TA, Hakim RMBalancing fistula first with catheters last . Am J Kidney Dis. 2007; 50(3):379-395.
8.
Littler P., Cullen N., Gould D., Bakran A., Powell S.Angiojet thrombectomy for occluded dialysis fistulae: outcome data. Cardiovasc Intervent Radiol.2009;32(2):265-270.
Patel AA, Tuite CM, Trerotola SOMechanical thrombectomy of hemodialysis fistulae and grafts. Cardiovasc Intervent Radiol. 2005;28(6):704-713.
11.
Vesely TM, Amin MZ, Pilgram T.Use of stents and stent grafts to salvage angioplasty failures in patients with hemodialysis grafts. Semin Dial. 2008 ;21(1):100-104.
12.