The usefulness of the alanine dosimeter for proton beams has been demonstrated before. In this paper a literature overview is given of the application of alanine in proton beam dosimetry. The energy dependence of the dosimeter has been investigated and Monte Carlo calculations were performed to investigate the influence of this energy dependence on a Bragg curve as well as to explain some phenomena related to the use of alanine in a solid phantom that were reported in the literature.
BradshawW. W.CadenaD. G.Jr.CrawfordG. W.SpetzlerH. A. W.The Use of Alanine as a Solid Dosimeter. Radiat. Res.17, 11–21 (1962).
2.
EbertP. J.HardyK. A.CadenaD. G.Energy Dependence of Free Radical Production in Alanine. Radiat. Res.26, 178–197 (1965).
3.
HansenJ. W.OlsenK. J.Theoretical and Experimental Radiation Effectiveness of the Free Radical Dosimeter Alanine to Irradiation with Heavy Charged Particles. Radiat. Res.104, 15–27 (1985).
4.
FattibeneP.CalicchiaA.d'ErricoF.DeAngelisC.EggerE.OnoriS.Preliminary Assessment of LiF and Alanine Detectors for the Dosimetry of Proton Therapy Beams. Radiat. Prot. Dosim.66, 305–309 (1996).
5.
OnoriS.d'ErricoF.DeAngelisC.EggerE.FattibeneP.JanovskyI.Proton Response of Alanine Based Pellets and Films. Appl. Radiat. Isot.47, 1201–1204 (1996).
6.
OnoriS.d'ErricoF.De-AngelisC.EggerE.FattibeneP.JanovskyI.Alanine Dosimetry of Proton Therapy Beams. Med. Phys.24, 447–453 (1997).
7.
VynckierS.BonnettD. E.JonesD. T. L.Code of Practice for Clinical Proton Dosimetry. Radiother. Oncol.20, 53–63 (1991).
8.
VynckierS.BonnettD. E.JonesD. T. L.Supplement to the Code of Practice for Clinical Proton Dosimetry. Radiother. Oncol.32, 174–179 (1994).
9.
ICRU, Clinical Proton Dosimetry Part I: Beam Production, Beam Delivery and Measurement of Absorbed Dose. International Commission on Radiation Units and Measurements Report 59, ICRU, Bethesda, USA (1998).
10.
CuttoneG.RaffaeleL.TonghiL.RovelliA.SabiniM. G.EggerE.KacperekA.BraiM.BartolottaA.TeriG.OnoriS.FattibeneP.First Dosimetry Intercomparison Results for the CATANA Project. Phys. Medica15, 121–130 (1999).
11.
BartolottaA.TonghiL. B.BraiM.CuttoneG.FattibeneP.OnoriS.RaffaeleL.RovelliA.SabiniM. G.TeriG.Response Characteristics of Thermoluminescence and Alanine-based Dosemeters to 16 and 25 MeV Proton Beams. Radiat. Prot. Dosim.85, 353–356 (1999).
12.
FattibeneP.De AngeliS. C.OnoriS.CherubiniR.Alanine Response to Proton Beams in the 1.6–6.1 MeV Energy Range. Radiat. Prot. Dosim.101, 465–468 (2002).
13.
WaligorskiM. P. R.DanialyG.LohK. S.KatzR.The Response of the Alanine Detector After Charged-particle and Neutron Irradiations. Appl. Radiat. Isot.40, 923–933 (1989).
14.
HansenJ. W.OlsenK. J.WilleM.The Alanine Radiation Detector for High and Low-LET Dosimetry. Radiat. Prot. Dosim.19, 43–47 (1987).
15.
HenriksenT.Production of Free Radicals in Solid Biological Substances by Heavy Ions. Radiat. Res.27, 676–693 (1966).
16.
NichiporovD.KostjuchenkoV.PuhlJ. M.BensenD. L.DesrosiersM. F.DickC. E.McLaughlinW. L.KojimaT.CourseyB. M.ZinkS.Investigation of Applicability of Alanine, and Radiochromic Detectors to Dosimetry of Proton Clinical Beams. Appl. Radiat. Isot.46, 1355–1362 (1995).
ICRU, Stopping Powers and Ranges for Protons and Alpha Particles. International Commission on Radiation Units and Measurements Report 49, ICRU, Bethesda, USA (1993).
19.
ICRU, Stopping Powers for Electrons and Positrons. International Commission on Radiation Units and Measurements Report 37, ICRU, Bethesda, USA (1984).
20.
ICRU, Nuclear Data for Neutron and Proton Radiotherapy and for Radiation Protection Dose. International Commission on Radiation Units and Measurements Report 37, ICRU, Bethesda, USA (2000).
21.
SchneiderU.PemlerP.BessererJ.DellertM.MoosburgerM.de BoerJ.PedroniE.BoehringerT.The Water Equivalence of Solid Materials used for Dosimetry with Small Proton Beams. Med. Phys.29, 2946–2951 (2002).
22.
PalmansH.SymonsJ. E.DenisJ-M.de KockE. A.JonesD. T. L.VynckierS.Fluence Correction Factors in Plastic Phantoms for Clinical Proton Beams. Phys. Med. Biol.47, 3055–3071 (2002).
23.
BergerM. J.Proton Monte Carlo Transport Program PTRAN. National Institute for Standards and Technology Report NISTIR 5113, (Gaithersburg: NIST) (1993).
24.
PalmansH.VerhaegenF.Calculated Depth Dose Distributions for Proton Beams in Some Low-Z Materials. Phys. Med. Biol.42, 1175–1183 (1997).
25.
PalmansH.VerhaegenF.Monte Carlo Study of Fluence Perturbation Effects on Cavity Dose Response in Clinical Proton Beams. Phys. Med. Biol.43, 65–89 (1998).
26.
PalmansH.OlkoP.BilskiP.HeeseJ.Calculations of Relative Dose Deposition and Primary Proton Spectra in LiF-TLD's in a 70 MeV Proton Beam. Med. Biol. Eng. Comput.35 Suppl. 2, 975 (1997).
27.
AndreoP.BurnsD. T.HohlfeldK.HuqM. S.KanaiT.LaitanoF.SmythV. G.VynckierS.Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water. Technical Report Series 398, IAEA, Vienna, Austria (2000).
28.
GoiteinM.SistersonJ. M.The Influence of Thick Inhomogeneities on Charged Particle Beams. Radiat. Res.74, 217–230 (1978).