Rousseau H., Puel J., Joffre F., et al. Self-expanding endovascular prosthesis: An experimental study . Radiology164:709-714, 1987.
5.
Cragg AH, Lund G., Rysavy J., et al. Nonsurgical placement of arterial endoprostheses: A new technique using nitinol wire. Radiology147:216-226, 1983.
6.
Tegtmeyer CJ , Hartwell GD, Selby JB, et al. Results and complications of angioplasty in aortoiliac disease. Circulation 83[Suppl I]:I-53-I-60, 1991.
7.
Murphy TP, Cronan JJ, Paolella LP, et al. Arterial rupture without balloon rupture during percutaneous transluminal angioplastyJ Vasc Surg6:528-530, 1987.
8.
Jensen SR, Voegeli DR, Crummy AB, et al. Iliac artery rupture during transluminal angioplasty: Treatment by embolization and surgical bypass. AJR145:381-382, 1985.
9.
Belli AM, Cumberland DC, Knox AM, et al. The complication rate of percutaneous peripheral balloon angioplastyClin Radiol41:380, 1990.
10.
Harris RW, Dulawa LB, Andros G., et al. Percutaneous transluminal angioplasty of the lower extremities by the vascular surgeon. Ann Vasc Surg5:345, 1991.
11.
Collins RH, Voorhees AB, Reemtsma K., et al. Efficacy of percutaneous angioplasty in lower extremity arterial occlusive disease. J Cardiovasc Surg (Torino) 25:390, 1984.
12.
Knight RW, Stanson AW, Johnson CM, et al. Percutaneous transluminal angioplasty: Results and surgical implications. Am J Surg147:578, 1984.
13.
Simonetti G. , Rossi P., Passariello R., et al. Iliac artery rupture: A complication of transluminal angioplasty. AJR140:989-990, 1983.
14.
Johnston KWIliac arteries: Reanalysis of results of balloon angioplasty. Radiology186:207-212, 1993.
15.
Palmaz JC, Laborde JC, Rivera FJ, et al. Stenting of the iliac arteries with the Palmaz stent: Experience from a multicenter trial. Cardiovasc Intervent Radiol15:291-297, 1992.
16.
Hausegger KA , Lammer J., Hagen B., et al. Iliac artery stenting: Clinical experience with the Palmaz stent, Wallstent, and Strecker stent. Acta Radiol33:292-296, 1992.
17.
Long AL, Page PE, Raynaud AC, et al. Percutaneous iliac artery stent: Angiographic long-term follow-up . Radiology180:771-778, 1991.
18.
Hausegger KA , Cragg AH, Lammer J., et al. Iliac artery stent placement: Clinical experience with a nitinol stent. Radiology190:199-202, 1994.
19.
Davies RP, Voyvodic F.Percutaneous retrieval of a partially expanded iliac artery stent: Case report . Cardiovasc Intervent Radiol15:120-122, 1992.
20.
Liermann D. , Strecker EP, Peters J.The Strecker stent: Indications and results in iliac and femoropopliteal arteries . Cardiovasc Intervent Radiol15:298-305, 1992.
21.
Raillat C., Rousseau H., Joffre F., et al. Treatment of iliac artery stenoses with the Wallstent endoprosthesis . AJR154:613-616, 1990.
22.
Vorwerk D., Gunther RWStent placement in iliac arterial lesions: Three years of clinical experience with the Wallstent. Cardiovasc Intervent Radiol15:285-290, 1992.
23.
Blum U., Gabelmann A., Redecker M.Percutaneous recanalization of iliac artery occlusions: Results of a prospective studyRadiology189:536-540, 1993.
24.
Samson RH, Sprayregen S., Veith FJ, et al. Management of angioplasty complications, unsuccessful procedures and early and late failures. Ann Surg199:234-240, 1984.
25.
Gardiner GA Jr, Meyerovitz MF, Stokes KR, et al. Complications of transluminal angioplasty . Radiology159:201-208, 1986.
26.
Becker GJ, Palmaz JC, Rees CR, et al. Angioplasty-induced dissections in human iliac arteries: Management with Palmaz balloon-expandable intraluminal stents. Radiology176:31-38, 1990.
27.
Chalmers N. , Eadington DW, Gandanhamo D., et al. Case report: Infected false aneurysm at the site of an iliac stent. Br J Radiol66:946-948, 1993.
28.
Therasse E. , Soulez G., Cartier P., et al. Infection with fatal outcome after endovascular metallic stent placement. Radiology192:363-365, 1994.
29.
Gunther RW, Vorwerk D., Antonucci F., et al. Iliac artery stenosis or obstruction after unsuccessful balloon angioplasty: Treatment with a self-expandable stent. AJR156:389-393, 1991.