O'Leary DH , Kane RA, Chase BNA prospective study of the efficacy of B-scan sonography in the detection of deep venous thrombosis in the lower extremities . JCU16:1-8, 1988.
Taylor KJW , Burns PN, Woodcock JP, Wells PNT Blood flow in deep abdominal and pelvic vessels: Ultrasonic pulsed Doppler analysis. Radiology154:487-493, 1985.
5.
Nicholls SC, Kohler TR, Martin RL, Strandness DE Jr.Use of hemodynamic parameters in the diagnosis of mesenteric insufficiency . J Vasc Surg3:507-510, 1986.
6.
Moneta GL, Strandness DE Jr. Peripheral arterial duplex scanning. JCU15:645-651, 1987.
7.
Vatner SF, Franklin D., Van Citters RLMesenteric vasoactivity associated with eating and digestion in the conscious dog. Am J Physiol219:170-174, 1970.
8.
Moneta GL, Taylor DC, Helton WS, Mulholland MW, Strandness DE Jr.Duplex ultrasound measurement of postprandial intestinal blood flow: Effect of meal composition. Gastroenterology95:1294-1301, 1988.
9.
Jager K., Bollinger A., Valli C., Ammann R.Measurement of mesenteric blood flow by duplex scan. J Vasc Surg3:462-469, 1986.
10.
Flinn WR, Sandager GP, Lilly M., Yao JST, Bergan JJDuplex scan of the mesenteric and celiac arteries. In Bergan JJ, Yao JST , eds. Arterial Surgery: New Diagnostic and Operative Techniques . Orlando, Fla: Grune & Stratton , 1988, pp 367-375.
11.
Kohler TR, Zierler RE, Martin RL, Nicholls SC, Bergelin RO, Kazmers A., Beach KW, Strandness DE Jr.Noninvasive diagnosis of renal artery stenosis by ultrasonic duplex scanning . J Vasc Surg4:450-456, 1986.
12.
Taylor DC, Kettler MD, Moneta GL, Kohler TR, Kazmers A., Beach KW, Strandness DE Jr.Duplex ultrasound scanning in the diagnosis of renal artery stenosis: A prospective evaluation. J Vasc Surg7:363-369, 1988.
13.
Rittgers SE , Norris CS, Barnes RW Detection of renal artery stenosis: Experimental and clinical analysis of velocity waveforms. Ultrasound Med Biol11:523-531, 1985.
14.
Hauda N., Fukunaga R., Hideki E., Yoneda S., Kimura K., Kamada T.Efficacy of echo-Doppler examination for the evaluation of renovascular disease . Ultrasound Med Biol14:1-5, 1988.
15.
Jager KA, Phillips DJ, Martin RL, Hanson C., Roederer GO, Langlois YE, Ricketts HJ, Strandness DE Jr.Noninvasive mapping of lower arterial lesions. Ultrasound Med Biol11: 515-521, 1985.
16.
Kohler TR, Nance DR, Cramer MM, Vandenburghe N., Strandness DE Jr.Duplex scanning for diagnosis of aortoiliac and femoropopliteal disease: A prospective study. Circulation76: 1074-1080, 1987.
17.
Barnes RWUtility of duplex scanning of the renal artery. In Bergan JJ, Yao JST , eds. Arterial Surgery: New Diagnostic and Operative Techniques . Orlando, Fla.: Grune & Stratton , 1988, pp 351-366.
18.
Eidt JF, Fry RE, Clagett GP, Fisher DF, Alway C., Fry WJPostoperative follow-up of renal artery reconstruction with duplex ultrasound . J Vasc Surg8:667-673, 1988.
19.
Taylor DC, Moneta GL, Strandness DE Jr.Follow-up of renal artery stenosis by duplex ultrasound. J Vasc Surg5:137-147, 1987.
20.
Okuhn SP, Reilly LM, Bennett JB III, Hughes L., Goldstone J., Ehrenfeld WK, Stoney RJIntraoperative assessment of renal and visceral artery reconstruction: The role of duplex scanning and spectral analysis. J Vasc Surg5:137-147, 1987.
21.
Ferretti G. , Salomine A., Malfi B., Segoloni GPDuplex scanning and the transplanted kidney . Lancet1:219, 1986.
22.
Taylor KJW , Morse SS, Rigsby CM, Bia M., Schiff M. Vascular complications in renal allografts: Detection with duplex Doppler US. Radiology162:31-38, 1987.
23.
Nenmyer MM, Gifford RRM, Thiele BLIdentification of early rejection in renal allografts with duplex ultrasonography . J Vasc Technol12:19-23, 1988.
24.
Cummings C., Loboa L., Norman D., Porter JM, Taylor LMProspective evaluation of duplex scanning with color Doppler for diagnosis of renal allograft rejection. J Vasc Techol13: 91-94, 1989.
25.
Needleman L. , Kurtz ABDoppler evaluation of the renal transplant . JCU15:661-673, 1987.
26.
Steinberg HV , Nelson RC, Murphy FB, Chezmer JL, Baumgartner BR, Delaney VB, Whelchel JD, Bernardino MERenal allograft rejection: Evaluation by Doppler US and MR imaging. Radiology162:337-342, 1987.
27.
Moneta GL, Strandness DE Jr. Basic data concerning noninvasive vascular testing. Ann Vasc Surg3:190-193, 1989.
28.
Ubhi CS, Irving HC, Norwood HM, Guilley PJ, Giles GRMonitoring of renal allografts by Doppler ultrasound. Ann R Coll Surg Engl69:229-232, 1987.
29.
Rifkin MD, Needleman L., Pasto ME, Kurtz AB, Foy PM, McGlynn E., Canino C., Baltarowich OH, Pennell RG, Goldberg BBEvaluation of renal transplant rejection by duplex Doppler examination: Value of the resistive index. AJR148:759-762, 1987.
30.
Taylor DC, Moneta GL, Cramer MM, Strandness DE Jr.Extrinsic compression of the celiac artery by the median arcuate ligament of the diaphragm: Diagnosis by duplex ultrasound. J Vasc Technol11:236-238, 1987.
31.
Sandager G. , Flinn WR, McCarthy WJ, Yao JST, Bergan JJAssessment of visceral arterial reconstruction using duplex scan. J Vasc Technol11:13-16, 1987.
32.
Lilly MP, Harward TRS, Flinn WR, Blackburn DR, Astleford PM, Yao JST.Duplex ultrasound measurement of changes in mesenteric flow velocity with pharmacologic alteration of intestinal blood flow in man. J Vasc Surg9:18-25, 1989.
33.
Longley DG, Skolnick ML, Zajko AB, Bron KMDuplex Doppler sonography in the evaluation of adult patients before and after liver transplantation. AJR151:687-696, 1988.
34.
Dalen K., Day DL, Ascher NL, Hunter DW, Thompson WM, Cantaneda-Zuniga WR, Letourneau JGImaging of vascular complications after hepatic transplantation. AJR150: 1285-1290, 1988.
35.
Ackroyd N., Gill R., Griffiths K., Kossoff G., Reeve T.Duplex scanning of the portal vein and portasystemic shunts. Surgery99:591-597, 1986.
Flint EW, Sumkin JH, Zajko AB, Bowen ADDuplex sonography of hepatic artery thrombosis after liver transplantation . AJR151:481-483, 1988.
38.
Segel MC, Zajko AB, Bowen A., Bron KM, Skolnick ML, Penkrot RJ, Starzl TEHepatic artery thrombosis after liver transplantation: Radiologic evaluation . AJR146:137-141, 1986.
39.
Jager K., Johl H., Seifert H., Bollinger A.Perkutane transluminale angioplastie (PTA) ohne vorausgehende diagnosische arteriographie. Vasa [Suppl]15:24, 1986.
40.
Kohler TR, Nance DR, Strandness DE Jr. Can duplex scanning replace arteriography for lower extremity arterial diseaseAnn Vasc Surg (in press).
41.
Hatle L., Angelsen B.Physics of blood flow. In Hatle L, Angelsen B, eds. Doppler Ultrasound in Cardiology . Philadelphia: Lea & Febiger , 1985, pp 8-31.
42.
Hatle L., Burbakk A., Tromsdal A., Angelsen B.Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound . Br Heart J40:131-140, 1978.
43.
Faccenda F., Usui Y., Spencer MPDoppler measurement of the pressure drop caused by arterial stenosis: An experimental study; A case report. Angiology36:899-905, 1985.
44.
Kohler TR, Nicholls SC, Zierler RE, Beach KW, Schubart PJ, Strandness DE Jr.Assessment of pressure gradient by Doppler ultrasound: Experimental and clinical observations. J Vasc Surg6:460-469, 1987.
45.
Peterson GJ, Schwartz R., Woods JJThe use of deep duplex scanning to predict hemodynamically significant aortoiliac stenoses. J Vasc Surg7:395-399, 1988.
46.
Thiele BL, Hutchinson KL, Green FMPulsed Doppler waveform patterns produced by smooth stenosis in the dog thoracic aorta. In Taylor DEM, Steven AL, eds. Blood Flow, Theory and Practice. London: Academic Press , 1983.