LinZTsangCChowTFongKYaoT. A case study of the energy saving potential of stratum ventilation. Int J Vent2011; 9: 329–336.
8.
SchiavonSMelikovASekharC. Energy analysis of the personalized ventilation system in hot and humid climates. Energy Build2010; 42: 699–707.
9.
MelikovACermakRMajerM. Personalized ventilation: evaluation of different air terminal devices. Energy Build2002; 34: 829–836.
10.
LiXChenJ. Evolution of contaminant distribution at steady airflow field with an arbitrary initial condition in ventilated space. Atmos Environ2008; 42: 6775–6784.
11.
MaXLiXShaoXJiangX. An algorithm to predict the transient moisture distribution for wall condensation under a steady flow field. Build Environ2013; 67: 56–68.
12.
ShaoXMaXLiXLiangC. Fast prediction of non-uniform temperature distribution: a concise expression and reliability analysis. Energy Build2017; 141: 295–307.
13.
LiXZhuF. Response coefficient: a new concept to evaluate ventilation performance with “pulse” boundary conditions. Indoor Built Environ2009; 18: 189–204.
14.
LiangCShaoXMelikovALiX. Cooling load for the design of air terminals in a general non-uniform indoor environment oriented to local requirements. Energy Build2018; 174: 603–618.
15.
LiangCShaoXLiX. The impact of air distribution on the local cooling/heating load in a non-uniform indoor air environment. In Ventilation 2015: Proceedings of the 11th International Conference on Industrial Ventilation,Shanghai, China, 26–28 October 2015. REHVA and Tongji University, pp309–319.
16.
LiangCLiXShaoXLiB. Direct relationship between the system cooling load and indoor heat gain in a non-uniform indoor environment. Energy2020; 191: 116490.
17.
LiangCLiX. Influencing factors of ventilation rate to satisfy a local zone in a ventilated space. In: Proceedings of the Roomvent and Ventilation 2018 Conference, Espoo, Finland, 2–5 June 2018, Finnish Society of Indoor Air Quality and Climate (FiSIAQ) and Aalto University, 229–234.
18.
ZhaoJShaoXLiXLiangCWangHXuW. Theoretical expression for clean air volume in cleanrooms with non-uniform environments. Build Environ2021; 204: 108168.
19.
ZhangTChenQ. Identification of contaminant sources in enclosed environments by inverse CFD modeling. Indoor Air2007; 17: 167–177.
20.
ZhangTLiHWangS. Inversely tracking indoor airborne particles to locate their release sources. Atmos Environ2012; 55: 328–338.
21.
ShaoXLiXMaH. Identification of constant contaminant sources in a test chamber with real sensors. Indoor Built Environ2016; 25: 997–1010.
22.
WangHWangGLiX. Image-based occupancy positioning system using pose-estimation model for demand-oriented ventilation. J Build Eng2021; 39: 102220.
23.
ShaoXLiXMaXLiangC. Multi-mode ventilation: an efficient ventilation strategy for changeable scenarios and energy saving. Build Environ2017; 115: 332–344.