Abstract
A precast concrete structure reinforced by steel-fiber-reinforced polymer (FRP) composite bars (SFCBs) shows good durability and controllable post-yield stiffness, which makes this kind of structure suitable for marine infrastructure. The connection technology is one of the critical issues of a precast concrete structure with hybrid reinforcement. This paper presents an experimental study on the bond-slip testing (27 pullout specimens) of composite bars connected by a grouted deformed pipe splice (GDPS) connector with different bond lengths. The reinforcement included SFCBs and pure FRP bars. The test results showed that the failure modes could be classified into three categories: rebar pullout before or after the inner steel bar yielded, rupture of the FRP wrapped on the SFCB, and mixed failure of bar pullout with a partial fiber fracture. The average bond strength of the ordinary steel bar was approximately 146.8% that of the SFCB connector with the same anchored length. When the anchored length of the SFCB specimen was 15
Keywords
Get full access to this article
View all access options for this article.