Although duplex ultrasonography offers a number of theoretical and practical advantages over arteriography for the assessment of lower limb arterial disease, it has not yet been widely accepted into clinical practice. This article reviews the current status of lower limb arterial duplex and concludes that arteriography should no longer be regarded as the diagnostic ‘gold-standard’ and that duplex ultrasonography should now be the first line investigation in patients with lower limb arterial disease.
SeldingerS T. Catheter placement of the needle in percutaneous arteriography: A new technique. Acta Radiol1953; 39: 368–76.
2.
DavisP CHoffmanJ CJr. Work in progress: Intra-arterial digital subtraction angiography: Evaluation in 150 patients. Radiology1983; 148: 9–15.
3.
SmithT PCraggA HBerbaumK SNakagawaN. Comparison of the efficacy of digital subtraction and film-screen angiography of the lower limb: Prospective study in 50 patients. Am J Roentgenol1992; 158: 431–36.
4.
HesselS JAdamsD FAbramsH L. Complications of angiography. Radiology1981; 138: 273–81.
5.
ThieleB LStrandnessD E. Accuracy of angiographic quantification of peripheral atherosclerosis. Progr Cardiovasc Dis1983; 26: 223–36.
6.
ThompsonR WReadR DSlaydenJ EBoydC M. The role of primary and secondary profundaplasty in the treatment of vascular insufficiency. J Cardiovasc Surg1977; 18: 55–62.
7.
SlotH BStrijboschLGreepJ M. Interobserver variability in singleplane aortography. Surgery1981; 90: 497–503.
8.
SumnerD SStrandnessD E. Aortoiliac reconstruction in patients with combined iliac and superficial femoral arterial occlusion. Surgery1978; 84: 348–55.
BlairJ-FBandykD F. Real-time colour Doppler in arterial imaging. In: YaoJ S TPearceW H eds. Technologies in vascular surgery. Philadelphia: WB Saunders, 1992: 129–49.
11.
PolakJ FKarmelM IMannickJ AO'LearyD HDonaldsonM CWhittemoreA D. Determination of the extent of lower extremity peripheral disease with colour assisted duplex sonography: Comparison with angiography. Am J Roentgenol1990; 155: 1085–89.
12.
MayA GDe WeeseJ ARobC G. Haemodynamic effects of arterial stenosis. Surgery1963; 53: 513–24.
13.
MannF CHerrickJ FEssexH EBaldesE J. The effect on the blood flow of decreasing the lumen of a blood vessel. Surgery1938; 4: 249–52.
14.
MayA GVan de BergLDeWeeseJ ARobC G. Critical arterial stenosis. Surgery1963; 54: 250–59.
15.
LegemateD ATeeuwenCHoeneveldHAckerstaffR G AEikelboomB C. Spectral analysis criteria in duplex scanning of aortoiliac and femoropopliteal arterial disease. Ultrasound Med Biol1991; 17: 769–76.
16.
MonetaG LYaegerR ALeeR WPorterJ M. Noninvasive localisation of arterial occlusive disease: A comparison of segmental Doppler pressures and arterial duplex scanning. J Vasc Surg1993; 17: 578–82.
CossmanD VEllisonJ EWagnerW H. Comparison of contrast arteriography to arterial mapping with color-flow duplex imaging in the lower extremities. J Vasc Surg1989; 10: 522–99.
19.
JagerK APhillipsR LHansonC. Noninvasive mapping of lower limb arterial lesions. Ultrasound Med Biol1985; 11: 515–21.
20.
RankeCCreutzigAAlexanderK. Duplex scanning of the peripheral arteries: Correlation with angiographic diameter reduction. Ultrasound Med Biol1992; 18: 433–40.
21.
EvansD HMacphersonD SAsherM JBentleySBellP R F. Changes in Doppler ultrasound sonograms at varying distances from stenoses. Cardiovasc Res1982; 16: 631–36.
22.
WhymanM RHoskinsP RLengG C. Accuracy and reproducibility of duplex ultrasound imaging in a phantom model of femoral artery stenosis. J Vasc Surg1993; 17: 524–30.
23.
KohlerT RNanceD RCramerM MVandenburghieNStrandnessD E. Duplex scanning for diagnosis of aortoiliac and femoropopliteal disease: A prospective study. Circulation1987; 76: 1074–80.
24.
DemesMSokaADubravaMKostolnyM. Duplex ultrasound examination of arteries of lower extremities: Comparison with angiography. Vnitr Lek1989; 4: 358–62.
25.
Van der HeijdenF H W MLegemateD AVan LeeuwenM SMaliW P T MEikelboomB C. Spectral analysis criteria in duplex scanning of aortoiliac and femoropopliteal arterial disease. Ultrasound Med Biol1991; 17: 71–76.
26.
CollierPWilcoxGBrooksDLaffeySDaltonT. Improved patient selection for angioplasty utilizing color Doppler imaging. Am J Surg1990; 160: 171–74.
LengG CWhymanM RDonnanP T. Accuracy and reproducibility of duplex ultrasonography in grading femoropopliteal stenoses. J Vasc Surg1993; 17: 510–17.
29.
AllardLCloutierGDurandL GRoedererG. O.LangloisY. E.Limitations of ultrasonic duplex scanning for diagnosing lower limb arterial stenoses in the presence of adjacent segment disease. J Vasc Surg1994; 19: 650–57.
30.
SensierYHartshorneTThrushANydahlSBoliaALondonN J M. A prospective comparison of lower limb colour-coded duplex scanning with arteriography. Eur J Vasc Endovasc Surg1996; 11: 170–75.
31.
CurrieI CWilsonY GDaviesA H. Pulses-generated run-off versus dependent Doppler ultrasonography for assessment of calf vessel patency. Br J Surg1994; 81: 1448–50.
32.
RoedersheimerL RFeinsRGreenR M. Doppler evaluation of the pedal arch. Am J Surg1981; 142: 601–604.
33.
ShearmanC PGwynnB RCurranFGannonM XSimmsM H. Non-invasive femoropopliteal assessment: Is that angiogram really necessary?BMJ1986; 293: 1086–89.
34.
CampbellW BFletcherE LHandsL J. Assessment of the distal lower limb arteries: A comparison of arteriography and Doppler ultrasound. Ann R Coll Surg Engl1986; 68: 37–39.
35.
ScottD JHorrocksE HKinsellaDHorrocksM. Preoperative assessment of the pedal arch using pulse generated runoff and subsequent femorodistal outcome. Eur J Vasc Surg1994; 8: 20–25.
36.
LegemateD ATeeuwenCHoeneveldHAckerstaffR G AEikelboomB C. The potential of duplex scanning to replace aorto-iliac and femoropopliteal angiography. Eur J Vasc Surg1989; 3: 49–54.
37.
MulliganS AMatsudaTLanzerP. Peripheral arterial occlusive disease: Prospective comparison of MR angiography and colour duplex with conventional angiography. Radiology1991; 178: 695–700.
38.
ElsmanB H PLegemateD AVan der HeijdenF H W MDe VosH JMaliWPThMEikelboomB C. Impact of ultrasonographic duplex scanning on therapeutic decision making in lower limb arterial disease. Br J Surg1995; 82: 630–33.