Abstract
Background:
When hemodialysis arteriovenous accesses fail, autogenous options are often limited. Non-autogenous conduit choices include bovine carotid artery xenografts (BCAG) and expanded polytetrafluoroethylene (PTFE), yet their comparative effectiveness in hemodialysis access revision remains largely unknown.
Methods:
A cohort study was performed from a prospectively collected institutional database from August 2010 to July 2021. All patients undergoing an arteriovenous access revision with either BCAG or PTFE were followed for up to 3 years from their index access revision. Revision was defined as graft placement to address a specific problem of an existing arteriovenous access while maintaining one or more of the key components of the original access (e.g. inflow, outflow, and cannulation zone). Outcomes were measured starting at the date of the index revision procedure. The primary outcome was loss of secondary patency at 3 years. Secondary outcomes included loss of post-intervention primary patency, rates of recurrent interventions, and 30-day complications. Pooled logistic regression was used to estimate inverse probability weighted marginal structural models for the time-to-event outcomes of interest.
Results:
A total of 159 patients were included in the study, and 58% received access revision with BCAG. Common indications for revision included worn out cannulation zones (32%), thrombosis (18%), outflow augmentation (16%), and inflow augmentation (13%). Estimated risk of secondary patency loss at 3 years was lower in the BCAG group (8.6%, 3.9–15.1) compared to the PTFE group (24.8%, 12.4–38.7). Patients receiving BCAG experienced a 60% decreased relative risk of secondary patency loss at 3 years (risk ratio 0.40, 0.14–0.86). Recurrent interventions occurred at similar rates in the BCAG and PTFE groups, with 1.86 (1.31–2.43) and 1.60 (1.07–2.14) interventions at 1 year, respectively (hazard ratio 1.22, 0.74–1.96).
Conclusions:
Under the conditions of this contemporary cohort study, use of BCAG in upper extremity hemodialysis access revision decreased access abandonment when compared to PTFE.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.