Abstract
Background:
Hip periprosthetic fractures (PPF) after total hip arthroplasty (THA) are becoming increasingly prevalent. Their management is secondary to the fracture type and the stability of the implant. This study aimed to provide the outcomes of operatively managed PPF from a high-volume centre to help guide future decision making.
Methods:
This was a retrospective study of prospectively collected data from January 2008 to January 2021. Patient demographics, implant specific details, and fixation strategy were collected. Complications including infection, reoperation, re-fracture, re-revision, were collected. Short-term mortality was evaluated at 3 months and 1 year. P-values <0.05 were considered significant.
Results:
282 surgically managed PPF were identified. Vancouver B2 were predominant in 52% of the cases. Revision alone and revision with additional fixation were the most frequent strategies in 168 cases (60%). Complications requiring reoperation occurred in 20% of the cases, with infection as the most frequent (8.5%). Mortality rate was 7.8% at 3 months and 15.7% at 1 year, with significantly lower rates in B2 type. B2 fractures treated with cemented stems had a significantly lower 1-year mortality than distal fit revisions.
Conclusions:
PPF is associated with a high complication rate. Revision alone and revision with additional fixation remain the preferred method in B2/B3 type fractures, however, cemented revision can yield similar outcomes with lower short-term mortality. Considering the high-risk elderly and frail category of patients, a multidisciplinary team is necessary to improve outcomes and reduce mortality.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.