The average illuminance in a rectangular room with a reasonably regular lighting layout is obtained from measurements along two lines, at right angles to each other. The room average is then simply the product of the line averages, divided by the illuminance at the intersection of the two lines. The new method is simple, saves time and is of adequate accuracy, if the uniformity of illuminance is within accepted limits.