Abstract
Background:
SARS-CoV2 can cause pulmonary failure requiring prolonged invasive mechanical ventilation (MV). Lung protective ventilation strategies are recommended in order to minimize ventilator induced lung injury. Whether patients with COVID-19 have the same risk for complications including barotrauma is still unknown. Therefore, we investigated barotrauma in patients with COVID-19 pneumonia requiring prolonged MV.
Methods:
All patients meeting diagnosis criteria for ARDS according to the Berlin Definition, with PCR positive SARS-CoV2 infection and prolonged mechanical ventilation, defined as ≥2 days, treated at our ARDS referral center between March and April 2020 were included in a retrospective registry analysis. Complications were detected by manual review of all patient data including respiratory data, imaging studies, and patient files.
Results:
A total of 20 patients with severe COVID-19 pulmonary failure (Overall characteristics: median age: 61 years, female gender 6, median duration of MV 22 days) were analyzed. Eight patients (40%) developed severe barotrauma during MV (after median 18 days, range: 1-32) including pneumothorax (5/20), pneumomediastinum (5/20), pneumopericard (1/20), and extended subcutaneous emphysema (5/20). Median respirator settings 24 hours before barotrauma were: Peak inspiratory pressure (Ppeak) 29 cm H2O (range: 27-35), positive end-expiratory pressure (PEEP) 14 cm H2O (range: 5-24), tidal volume (VT) 5.4ml/kg predicted body weight (range 0.4-8.6), plateau pressure (Pplateau) 27 cm H2O (range: 19-30). Mechanical ventilation was significantly more invasive on several occasions in patients without barotrauma.
Conclusion:
Barotrauma in COVID-19 induced respiratory failure requiring mechanical ventilation was found in 40% of patients included in this registry. Our data suggest that barotrauma in COVID-19 may occur even when following recommendations for lung protective MV.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.
