Theoretical considerations are given to experimental data reduc tion for zone model validations. Three schemes to obtain averaged parameters of a thermodynamic system in nonequilibrium state are discussed in the light of model validation. Examples are given to demonstrate the difference between the zone average temperatures obtained from two averaging schemes.
Cook, N.H. and E. Rabinowicz.1963. Physical Measurement and Analysis, London: Addison-Wesley Publishing Company, Inc., p. 2.
2.
Friedman, R.1992. "An International Survey of Computer Models for Fire and Smoke," J. Fire Prot. Eng. , 4(3):81-92.
3.
Janssens, M.L. and H.C. Tran.1992. "Data Reduction of Room Tests for Zone Model Validation," Journal of Fire Sciences , 10:528-555.
4.
Cooper, L.Y. , M. Harkleroad, J. Quintiere and W. Rinkinen.1982. "An Experimental Study of Upper Hot Layer Stratification in Full-Scale Multi-Room Fire Scenarios ," Journal of Heat Transfer, 104:741-749.
5.
Steckler, K.D., J.G. Quintiere and W.J. Rinkinen.1982. "Flow Induced by Fire in a Compartment ," NBSIR 82-2520, U. S. Department of Commerce, National Bureau of Standards, National Engineering Laboratory, Center for Fire Research , Washington, DC 20234, September.
6.
Peacock, R.D. , S. Davis and V. Babrauskas.1991. "Data for Room Fire Model Comparisons," J. Res. Natl. Inst. Stand. Technol. , 96(4):411-462.
7.
Peacock, R.D. , W.W. Jones and R.W. Bukowski.1993. "Verification of a Model of Fire and Smoke Transport," Fire Safety J., 21:89-129.
8.
Reynolds, W. C. 1968. "Thermodynamics," McGraw-Hill Kogakusha, Ltd., Tokyo, p. 65.
9.
Kawagoe, K.1958. "Fire Behaviour in Rooms. Building Fire Research Institute ," Ministry of Construction (Japan), Report No. 27, Tokyo.
10.
Peacock, R.D. , G.P. Forney, P. Reneke, R. Portier and W.W. Jones.1993. " CFAST, the Consolidated Model of Fire Growth and Smoke Transport," NIST Technical Note 1299, Building and Fire Research Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899-0001, USA.
11.
Brani, D.M. and W.Z. Black.1992. "Two-Zone Model for a Single-Room Fire," Fire Safety J., 19:189-216.
12.
Quintiere, J.G.1995. "Compartment Fire Modeling," in The SFPE Handbook of Fire Protection Engineering, 2nd Edition, P. J. DiNenno (ed.), Society of Fire Protection Engineers, Boston, pp. 3.125-3.133.
13.
Birk, D.M.1991. An Introduction to Mathematical Fire Modeling, Lancaster, PA: Technomic Publishing Co., Inc.
14.
Prahl, J. and H.W. Emmons.1975. "Fire Induced Flow through an Opening ," Combustion and Flame, 25:369-385.
15.
He, Y. and V. Beck.1996. "Smoke Spread Experiment in a Multi Storey Building and Computer Modelling," to appear in Fire Safety Journal.