Urea and creatinine levels in spent hemodialysates showed only small declines in spite of incubation at 37° C for 36 hours. In the determination of dialysate-side solute removal, it would seem prudent to keep spent dialysate cold during collection to retard bacterial breakdown of these waste products.
GotchF.A., SargentJ.A.. A mechanistic analysis of the National Cooperative Dialysis Study (NCDS).Kidney Int1985; 28: 526–34.
2.
BloembergenW.E., StannardD.C., PortF.K.. Relationship of dose of hemodialysis and cause-specific mortality.Kidney Int1996; 50: 557–65.
3.
MovilliE.. Simplified approaches to calculate Kt/V. It's time for agreement.Nephrol Dial Transplant1996; 11: 24–7.
4.
EricssonF., Odar-CederlöfI., ErikssonC.G., LindgrenS., KjellstrandC.. Urea, creatinine, uric acid and phosphate spaces and their relationship to total body water during chronic hemodialysis.ASAIO Trans1998; 34: 346–50.
5.
SkroederR., JacobssonS., KjellstrandP., BobergU., KjellstrandC.M.. K and T covariate with V in hemodialysis. As K increases and T decreases, V also decreases.ASAIO Trans1991; 37: M129–32.
6.
KjellstrandC., SkroderR., Odar-CederlöfI., EricssonF., KjellstrandP., JacobsonS.. Patient related factors leading to slow urea transfer in the body during dialysis.ASAIO J1994; 40: 164–70.
7.
EllisP.W., MalcheskyP.S., MagnussonM.O., GoormasticM., NakamotoS.. Comparison of two methods of kinetic modeling.Trans Am Soc Artif Intern Organs1984; 30: 60–4.
8.
KeshaviahP.. The solute removal index-a unified basis for comparing disparate therapies.Perit Dial Int1995; 15: 101–4.
ChengY.L., ShekC.C., WongF.K.M.. Determination of the solute removal index with a partial dialysate collection method.Am J Kidney Dis1998; 31: 986–90.
11.
IngT.S., YuA.W., WongF.K.M., RafiqM., ZhouF.Q., DaugirdasJ.T.. Collection of a representative fraction of total spent hemodialysate.Am J Kidney Dis1995; 25: 810–2.
CharytanC., GuptaB., MeindelN., SpinowitzB.. Fractional direct dialysis quantification: A new approach for prescription and monitoring hemodialysis therapy.Kidney Int1996; 50: 1845–9.
14.
ArgilesA., FicheuxA., ThomasM.. Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement.Kidney Int1997; 52: 530–7.
15.
DepnerT.A., KeshaviahP.R., EbbenJ.P.. Multicenter clinical validation of an on-line monitor of dialysis adequacy.J Am Soc Nephrol1996; 7: 464–71.
16.
LeeW.C., TsaiC.J., HuangC.C.. Assessment of dialysis adequacy using the dialysate urea monitor: Preliminary experience of the dialysate urea monitor.Ren Fail1997; 19: 789–7.
17.
KiddE.E.. Bacterial contamination of dialysing fluid of artificial kidney.Br Med J1964; 1: 880–2.
18.
KleinE., PassT., HardingG.B., WrightR., MillionC.. Microbial and endotoxin contamination in water and dialysate in the central United States.Int J Artif Organs1990; 14: 85–94.
19.
Beck-SagueC.M., JarvisW.R., BlandL.A., ArduinoM.J., AgueroS.M., VerosicG.. Outbreak of gram-negative bacteremia and pyrogenic reactions in a hemodialysis center.Am J Nephrol1990; 10: 397–403.
LonnemannG.. Dialysate bacteriological quality and the permeability of dialyzer membranes to pyrogens.Kidney Int1993; 43(Suppl 41): S195–S200.
22.
BambauerR., SchauerM., JungW.K., DaumV., VienkenJ.. Contamination of dialysis water and dialysate: A survey of 30 centers.ASAIO J1994; 40: 1012–6.
23.
LaurenceR.A., LapierreS.T.. Quality of hemodialysis water. A 7-year multicenter study.Am J Kidney Dis1995; 25: 738–50.
24.
EbbenJ.P., HirschD.N., LuehmannD.A., CollinsA.J., KeshaviahP.R.. Microbiologic contamination of liquid bicarbonate concentrate for hemodialysis.ASAIO Trans1987; 33: 269–73.
25.
JansH., BretlauP., NielsenB.. Bacteriological contamination of dialyzers. Clinical, bacteriological and scanning electron-microscopic evaluation of different dialysate mixing systems.Nephron1978; 20: 10–7.
26.
FaveroM.S., CarsonL.A., BondW.W., PetersenN.J.. Factors that influence microbial contamination of fluids associated with hemodialysis machines.Appl Microbiol1974; 28: 822–30.
27.
FaveroM.S., PetersenN.J., BoyerK.M., CarsonL.A., BondW.W.. Microbial contamination of renal dialysis systems and associated health risks.Trans Am Soc Artif Intern Organs1974; 20: 175–83.
28.
McNultyC.A.M., WiseR.. Rapid diagnosis of campylobacter-associated gastritis.Lancet1985; 1: 1443–4.
29.
SampsonE.J., BairdM.A., BurtisC.A., SmithE.M., WittD.L., BayseD.D.. A coupled-enzyme equilibrium method for measuring urea in serum: Optimization and evaluation of the AACC Study Group on urea candidate reference method.Clin Chem1980; 26: 816–26.
30.
BartelsH., BohmerM., HeierliC.. Serum creatinine determination without protein precipitation.Clin Chim Acta1972; 37: 192–97.
31.
MaasA.H.R., KofstadJ., Siggaard-AndersenO.. eds: Ionized calcium, sodium, and potassium by ion selective electrodes. Vol. 5 Proceedings of the first meeting of the European working group on ion selective electrodes. IFCC Workshop, Oslo, Norway 1983. Copenhagen, Private Press, 1984.