Abstract
Background:
In managing pediatric knee conditions, an accurate bone age assessment is often critical for diagnostic, prognostic, and treatment purposes. Historically, the Greulich and Pyle atlas (hand atlas) has been the gold standard bone age assessment tool. In 2013, a shorthand bone age assessment tool based on this atlas (hand shorthand) was devised as a simpler and more efficient alternative. Recently, a knee magnetic resonance imaging (MRI) bone age atlas (MRI atlas) was created to circumvent the need for a left-hand radiograph.
Purpose:
To create a shorthand version of the knee MRI atlas.
Study Design:
Cohort study (diagnosis); Level of evidence, 2.
Methods:
A shorthand bone age assessment method was created utilizing the previously published MRI atlas, which utilizes several criteria that are visualized across a series of images. The MRI shorthand draws on characteristic criteria for each age that are best observed on a single MRI scan. For validation, we performed a retrospective assessment of skeletally immature patients. One reader performed the bone age assessment using the MRI atlas and the MRI shorthand on 200 patients. Then, 4 readers performed the bone age assessment with the hand atlas, hand shorthand, MRI atlas, and MRI shorthand on a subset of 22 patients in a blinded fashion. All 22 patients had a knee MRI scan and a left-hand radiograph within 4 weeks of each other. Interobserver and intraobserver reliability, as well as variability among observers, were evaluated.
Results:
A total of 200 patients with a mean age of 13.5 years (range, 9.08-17.98 years) were included in this study. Also, 22 patients with a mean age of 13.3 years (range, 9.0-15.6 years) had a knee MRI scan and a left-hand radiograph within 4 weeks. The intraobserver and interobserver reliability of all 4 assessment tools were acceptable (intraclass correlation coefficient [ICC] ≥ 0.8;
Conclusion:
The MRI shorthand is a simple and efficient means of assessing the skeletal maturity of adolescent patients with a knee MRI scan. This bone age assessment technique had interobserver and intraobserver reliability equivalent to or better than the standard method of utilizing a left-hand radiograph.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.
