The absorbed dose from 99Tcm-DTPA was estimated from 12 investigations in 9 patients who were evaluated for the patency of ventriculo-peritoneal shunts. The distribution of 99Tcm-DTPA in the ventricles, urinary bladder and peritoneal cavity was determined in regions of interest from repeated static gamma camera images. The effective dose equivalent was calculated to be less than 0.10 mSv for an injected activity of 15 MBq.
HarbertJ.: Radionuclide techniques in the evaluation of cerebrospinal fluid shunts. CRC Crit. Rev. in Diagn. Imaging.9 (1977), 207.
2.
ICRP: Recommendations of the international commission on radiological protection. ICRP Publication 26. Pergamon Press, Oxford, New York1977.
3.
JohanssonL.MattssonS.NosslinB.: Radiation doses from radioactive substances in medical use. Swedish National Institute of Radiation Protection, Stockholm 1981 (updated 1982 and 1983).
4.
JohanssonL.MattssonS.NosslinB.Effective dose equivalent from radiopharmaceuticals. Eur. J. Med.9 (1984), 485.
5.
SnyderW. S.FordM. R.WarnerG. G.WatsonS. B.: ‘S’, absorbed dose per unit cumulated activity for selected radionuclides and organs. MIRD pamphlet No. 11. Society of Nuclear Medicine, New York 1975.
6.
WikkelsøC.AnderssonH.LindbergS.BlomstrandC.: ‘Shuntography’. A radionuclide scanning method for evaluation of cerebrospinal fluid shunt patency. Nucl. Med. Comm.4 (1983), 88.