A new technique for determination of the bone mineral content in the vertebral body by means of a laterally directed roentgen ray beam is presented. By using a stable high voltage for the roentgen tube and a stable detector with very high energy resolution, the amount of bone mineral in the path of the radiation beam can be determined with correction for both fat and lean soft tissue. The results so far indicate that the technique is useful for objective determination of the bone mineral content in the vertebral body.
BengtssonG.BlomgrenP.-G.BergmanK.ÅbergL.: Patient exposures and radiation risks in Swedish diagnostic radiology. Acta radiol. Oncology17 (1978), 81.
2.
ChenC. S.DoiK.VybornyC.ChanH.-P.HoljeG.: Monte Carlo simulation studies of detectors used in the measurement of diagnostic x-ray spectra. Med. Phys.7 (1980), 627.
3.
HanssonT.RoosB.: The influence of age, height and weight on the bone mineral content of lumbar vertebrae. Spine5 (1980), 545.
4.
HanssonT.RoosB.: The relation between bone mineral content, experimental compression fractures, and disc degeneration in lumbar vertebrae. Spine6 (1981), 147.
5.
HanssonT.RoosB.: Microcalluses of the trabeculae in lumbar vertebrae and their relation to the bone mineral content. Spine6 (1981), 375.
6.
HanssonT.RoosB.: The amount of bone mineral and Schmorl's nodes in lumbar vertebrae. Spine8 (1983), 266.
7.
HanssonT.RoosB.NachemsonA.: Development of osteopenia in the fourth lumbar vertebra during prolonged bed rest after operation for scoliosis. Acta orthop. scand.46 (1975), 621.
8.
HanssonT.RoosB.NachemsonA.: The bone mineral content and ultimate compressive strength of lumbar vertebrae. Spine5 (1980), 46.
9.
LindquistO.BengtssonC.HanssonT.JonsonR.: Changes in bone mineral content of the axial skeleton in relation to ageing and the menopause. Scand. J. clin. Lab. Invest.43 (1983), 333.
10.
LindquistO.BengtssonC.HanssonT.RoosB.: Bone mineral content in relation to age and menopause in middle-aged women. Scand. J. clin. Lab. Invest.41 (1981), 215.
11.
RoosB. O.: Dual photon absorptiometry in lumbar vertebrae. II. Precison and reproducibility. Acta radiol. Ther. Phys. Biol.14 (1975), 291.
12.
RoosB. O.HanssonT. H.SköldbornH.: Dual photon absorptiometry in lumbar vertebrae. Evaluation of the baseline error. Acta radiol. Oncology19 (1980), 111.
13.
RoosB. O.SköldbornH.: Dual photon absorptiometry in lumbar vertebrae. I. Theory and method. Acta radiol. Ther. Phys. Biol.13 (1974), 266.
14.
SmithM. A.SuttonD.TothillP.: Comparison between 153Gd and 241Am, 137Cs for dual-photon absorptiometry of the spine. Phys. Med. Biol.28 (1983), 709.
15.
WaggenerR. G.RogersL. F.ZancaP.: A polychromatic x-ray beam to represent n monoenergetic photon sources. Bone Measurement Conference, Chicago, Ill. 1970. Proc. CONF-700515, p. 314.