Abstract
Background
Radiofrequency ablation (RFA) of subphrenic hepatocellular carcinomas (HCCs) using ultrasound (US) guidance presents a challenge.
Purpose
To evaluate local tumor progression (LTP) and overall survival (OS) after RFA of right posterior subphrenic HCCs, and to identify the risk factors for LTP and OS after RFA.
Material and Methods
We screened patients who underwent US-guided RFA for a single HCC <3 cm in the right posterior subphrenic area. Cumulative rates of LTP and OS were compared between multiple- and single-electrode treatments and artificial pleural effusion versus no-effusion groups using Kaplan–Meier curves and the log-rank test. The risk factors for LTP and OS were assessed.
Results
A total of 36 patients were included. The cumulative 5-year and 10-year LTP rates were 32.9% and 39.6%, respectively, and the corresponding OS rates were 72.2% and 48.7%, respectively. The multiple-electrode group had significantly lower cumulative LTP rates compared to the single-electrode group (P < 0.001). The group receiving artificial pleural effusion showed a trend towards lower LTP rates than the no-effusion group (P = 0.076). The albumin-bilirubin (ALBI) grade was the only risk factor for LTP (hazard ratio [HR] = 4.17, 95% confidence interval [CI] = 1.26–14.55; P = 0.020). A lower albumin level was a risk factor for mortality (HR = 0.24, 95% CI = 0.07–0.79; P = 0.020).
Conclusion
US-guided RFA with multiple electrodes and artificial pleural effusion tends to be linked with lower LTP rates. The ALBI grade and serum albumin level are risk factors for LTP and OS, respectively.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.