Abstract
Background
Kupffer cells (KC) have an important role in the host defense in obstructive cholangitis. Non-invasive monitoring of phagocytic function of KC is pivotal. Several studies showed the possibility of non-invasive monitoring of phagocytic function of KC using superparamagnetic iron oxide-enhanced magnetic resonance imaging (SPIO-MRI) or contrast-enhanced ultrasound (CEUS).
Purpose
To investigate the serial change of KC function using SPIO-MRI and CEUS and whether the SPIO-MRI parameter correlates with the CEUS parameter in obstructive cholangitis rat models.
Material and Methods
With our institutional Animal Care and Use Committee approval, 19 rats (common bile duct ligation [CBDL]: n = 9; control: n = 10) underwent SPIO-MRI and CEUS at baseline, two, and four weeks after CBDL. The relative signal loss (RSL) of T2* value on SPIO-MRI and Kupffer phase parenchymal echogenicity (KPE) on CEUS were measured. The correlation between SPIO-MRI and CEUS parameters were compared with KC count.
Results
In CBDL group, RSL and KPE had significantly decreased (72.1% to 29.5%, 2.7 to 0.4) at four weeks compared with those in the control group (68.2% to 58.3%, 2.5 to 3.0, P < 0.05). During the follow-up period, RSL showed significantly positive correlations with KPE (P = 0.007). In addition, at four weeks, we found RSL was positively correlated with KPE (ρ = 0.750, P = 0.002). KC count was negatively correlated to RSL and KPE at four weeks (ρ = −0.771, P = 0.001 and ρ = −0.644, P = 0.013).
Conclusion
SPIO-MRI and CEUS may be equally useful for monitoring the serial changes of KC phagocytic function in vivo.
Keywords
Get full access to this article
View all access options for this article.