Abstract
Background
Radiofrequency ablation (RFA) can be used to treat renal masses in patients where surgery is preferably avoided. As tumor size and location can affect ablation results, procedural planning needs to identify these factors to limit treatment to a single session and increase ablation success.
Purpose
To identify factors that may affect the primary efficacy of complete renal tumor ablation with radiofrequency after a single session.
Material and Methods
Percutaneous RFA (using an impedance based system) was performed using computed tomography (CT) guidance. Fifty-two renal tumors (in 44 patients) were retrospectively studied (median follow-up, 7 months). Data collection included patient demographics, tumor data (modified Renal Nephrometry Score, histopathological diagnosis), RFA treatment data (electrode placement), and follow-up results (tumor relapse). Data were analyzed through generalized estimating equations.
Results
Primary efficacy rate was 83%. Predictors for complete ablation were optimal electrode placement (
Conclusion
Optimal electrode placement and a long distance from the collecting system are associated with an increased primary efficacy of renal tumor RFA. These variables need to be considered to increase primary ablation success. Further studies are needed to evaluate the effect of RFA on histopathologically different renal tumors.
Keywords
Get full access to this article