The present study is aimed at characterizing the carbon dioxide (CO2) procedure in healthy subjects to achieve reliable provocation of anxiety symptoms.
Thirty healthy subjects inhaled in single-blind both compressed air and 7% CO2 mixture. Panic Symptom List (PSLIII-R), Visual Analogue Scale-Anxiety (VAS-A), State Anxiety Inventory (STAI-Y/1), respiratory parameters and skin conductance were measured. ‘Responders’ were classified depending on PSLIII-R scores after CO2. Twelve out of the 21 ‘responders’ performed a second test to assess test-retest repeatability.
In 21 subjects%VAS-A (45.4 32.1) and PSLIII-R (pre-test 2.3 2.1, post-test 17.5 8.2) but not STAI-Y/1, significantly increased during CO2 inhalation. Respiratory Rate, Minute Volume, end-Tidal CO2 and skin conductance rose in ‘responders’. Repeatability was studied with Bland-Altman plots, revealing mean difference between tests close to 0 for both%VAS-A and PSLIII-R. Among physiologic parameters, end-Tidal CO2 and Respiratory Rate showed good repeatability, with a within-subject CV of 9.2% and 6%, respectively.
The challenge produced measurable response in healthy subjects. Good test-retest repeatability was observed in ‘responders’. These data indicate that the test can be suitable for testing putative anti-panic or anxiolytic drugs in clinical studies using a within subject, crossover design.