OsbornJJBramsonMLGerbodeF.A rotating disc blood oxygenator and integral heat exchanger of improved inherent efficiency. J Thorac Cardiovasc Surg1959; 39: 427–37.
5.
OrtolanJY. Appareil automatique regulateur de debit et de niveau destine au circuit extracorporel d'une operation d'epuration sanguine. Brevet No. 69 846, France, 1971.
6.
TurinaMLitchfordBBabotaiIIntagliettaMBraunwaldNS. Servocontrolled extended cardiopulmonary bypass. Trans Am Soc Artif Intern Organs1973; 19: 504–10.
7.
HeuleJE. Blood level detector. Licence 413 692 USA, 1973.
8.
AlexanderBReadGGainsE. A. simple device for blood flow control in extracorporeal circuits. J Med Eng Technol1982; 6: 28–31.
9.
BarthelemyRBrieusselJMCouziHMorucciJP. Dispositif et moyens pour la regulation du debit de sang delivre par un systeme de circulation extracorporelle. Brevet No. 79 30666, France, 1979.
10.
ChauveauNBarthelemyRCouziHAutomatisation d'une circulation extracorporelle. Innov Techn Biol Med1980; 1: 33–49.
11.
ChauveauNBarthelemyRMorucciJP. Automation technique in extracorporeal circulation. World Congress on Med Phys Biomed Eng, Hamburg, September 5–11; 1982.
12.
ChauveauNBarthelemyRBrieusselJMCouziHRigaudBMorucciJP. Automatisation d'une circulation extracorporelle. Second Medit Confer Med Biol Eng, Marseille, September 15–19; 1980.
13.
BarthelemyRBrieusselJMCouziHMorucciJP. Dispositif et moyens pour regulation du debit de sang delivre par un systeme de circulation extracorporelle. Brevet No. 212 441, USA.
BagbyE.An extracorporeal flow formula for all patients. JECT1979; 11 (3): 101–106.
17.
SheppardLC. Computer control of the infusion of vasoactive drugs. Ann Biomed Eng1980; 8: 431–44.
18.
JuradoRAFitzkeeHLde AslaRALukbanSBLitwakRSOsbornJJ. Reduction of unexpected life-threatening events in postoperative cardiac surgical patients. The role of computerized surveillance. Circulation1977; 56 (Suppl 2): 44–49.
19.
SlateJB. Model-based design of a controller for infusing sodium nitroprusside during postsurgical hypertension. PhD Thesis, University of Wisconsin, Madison, 1980.
20.
de AslaRABenisAMJuradoRALitwakRS. Management of postcardiotomy hypertension by microcomputer-controlled administration of sodium nitroprusside. J Thorac Cardiovasc Surg1985; 89: 115–20.
21.
HammondJJKirdendallWMCalfeeRV. Hypertensive crisis managed by computer controlled infusion of sodium nitroprusside: a model for the closed loop administration of short acting vasoactive agents. Comput Biomed Res1979; 12: 97–108.
22.
PetreJHCosgroveDMEstafanousFG. Closed loop computerized control of sodium nitroprusside. Trans Am Soc Artif Intern Organs1983; 24: 501–505.
23.
SheppardLCKouchoukosNT. Automation of measurements and interventions in the sytemic care of postoperative cardiac surgical patients. Med Instrum1977; 11: 296.
24.
ShottsJF. Regulation of mean arterial pressure by computer control of vasoactive agents in postoperative patients. Computers in Cardiology, Proceedings IEEE, October 1975.
25.
GlaeserDHThomasLJ. Computer monitoring in patient care. Annual Review of Biophysics and Bioengineering. California Annual Reviews Inc1972; 1: 449–76.
26.
CoxJRNolleFMFozzardHAOliverGC. AZTEC: A preprocessing program for real time ECG rhythm analysis. IEEE Trans Biomed Eng1968; 15: 128–29.
27.
BushmanJA. The use of computers in the care of the acutely ill. In: PayneJPHillDW eds. Real time computering in patient management. GE Eng Peregrinus, 1976, WB 141, R228, 1975: 167–70.
28.
SheppardLCKouchoukosNTKurttsMAKirklinJW. Automated treatment of critically ill patients following operation. Ann Surg1968; 168: 596–604.
29.
StanleyTHBoamW.Use of the computer to monitor longterm cardiac assistance. J Thorac Cardiovasc Surg1969; 57: 519–26.
30.
OsbornJJBeaumontJORaisonJCARussellJ.Gerbode F. Measurement and monitoring of acutely ill patients by digital computer. Surgery1968; 64: 1057–70.
31.
PMSI. Perfusion monitoring system. Currently at prototype stage. From: Dictal Ltd, 2 Marston Court, Long Marston, Nr Tring, Herts, England.