Abstract
The average carbon intensity (gCO2e/kWh) of electricity provided by the UK National Grid is decreasing and becoming more time variable. This paper reviews the impact on energy calculations of using various levels of data resolution (half hourly, daily, monthly and annual) and of moving to region specific data. This analysis is in two parts, one focused on the potential impact on Part L assessments and the other on reported carbon emissions for existing buildings.
Analysis demonstrated that an increase in calculated emissions of up to 12% is possible when using an emissions calculation methodology employing higher resolution grid carbon intensity data. Regional analysis indicated an even larger calculation discrepancy, with some regions annual emissions increasing by a factor of ten as compared to other regions.
This paper proposes a path forward for the industry to improve the accuracy of analysis by using better data sources. The proposed change in calculation methodology is analogous to moving from using an annual average external temperature to using a CIBSE weather profile for a specific city or using a future weather file.