Abstract
In a retrospective comparison of blood loss following uncemented total knee replacement, in which either continuous or intermittent suction drainage was used, measured blood loss was significantly greater with continuous drainage. However, a method of calculating actual blood loss demonstrated no significant difference. With intermittent drainage, more blood remains undetected around the knee joint; this technique should therefore be abandoned in favour of continuous suction drainage.
References
1.
Erskine
J G
Fraser
C
Simpson
R
Protheroe
K
Walker
I D
(1981 ) Journal of the Royal College of Surgeons of Edinburgh
26 , 295 –297
2.
James
D C O
(1970 ) In: Scientific Foundations of Anaesthesia . Ed
Scurr
C F
Feldman
S A
. Heinemann , London ; p 284
3.
Klenerman
L
Mackie
I
Chakrabarti
R
Brozovil
M
Stirling
Y
(1977 ) Lancet
i , 970 –972
4.
Nakahara
M
Sakasashi
M
(1967 ) Journal of Bone and Joint Surgery
49A , 1345 –1351
5.
Newman
J H
Jackson
J P
Waugh
W
(1979 ) Journal of the Royal Society of Medicine
72 , 492 –494
6.
Pattison
E
Protheroe
K
Pringle
R M
1973 ) Annals of the Rheumatic Diseases
32 , 582 –584
7.
Ring
P A
(1979 ) Journal of Bone and Joint Surgery
61B , 123 –126