HeidelbergerMKendallFEHooSoo CM. Quantitative studies of the precipitin reaction. Antibody production in rabbits injected with azoprotein. J Exp Med1933; 58: 137–52
2.
AndersonRJSternbergJC. Immunoprecipitin measurement of serum proteins. In: RitchieRF, ed. Automated Immunoanalysis. New York and Basel: Marcel Dekker Inc, 1978; Part 2: 409–69
3.
ManciniGCarbonaraAOHeremansJF. Immunochemical quantitation of antigens by single radial immunodiffusion. Immunochemistry1965; 2: 235–54
4.
FaheyJLMcKelveyEM. Quantitative determination of serum immunoglobulins in antibody-agar plates. J Immunol1965; 94: 84–90
5.
BerneBH. Differing methodology and equations used in quantitating immunoglobulins by radial immunodiffusion. A comparative evaluation of reported and commercial techniques. Clin Chem1974; 20: 61–9
6.
LaurellCB. Quantitative estimation of proteins by electrophoresis in agarose gel containing antibodies. Anal Biochem1966; 15: 45–52
7.
BjerrumOJIngildALøwensteinHWeekeB. Quantitation of human IgG by rocket immunoelectrophoresis at pH 5 by use of carbamylated antibodies. A routine laboratory method. Clin Chim Acta1973; 46: 337–43
8.
WeekeB. Quantitative estimation of human immunoglobulins following carbamylation by electrophoresis in antibody containing agarose. Scand J Clin Lab Invest1968; 22: 107–11
9.
SlaterL. IgG, IgA and IgM by formylated rocket immunoelectrophoresis. Ann Clin Biochem1975; 12: 19–24
10.
LouKBowersJ. Electroimmunoquantitation of serum proteins cross-linked by glutaraldehyde. J Immunol Methods1975; 9: 69–79
TanfordC. Light scattering. In: Physical Chemistry of Macromolecules. New York: Wiley, 1961: 275–316
13.
HellsingK. Enhancing effects of nonionic polymers on immunochemical reactions. In: RitchieRF, ed. Automated Immunoanalysis. New York and Basel: Marcel Dekker Inc, 1978; Part 1: 67–112
14.
RitchieRFAlperCAGravesJA. Experience with a fully automated system of immunoassay of specific serum proteins. Arthritis Rheum1969; 12: 693
15.
WardAM. IgM. In: RitchieRF, ed. Automated Immunoanalysis, Part 1, New York and Basel: Marcel Dekker Inc, 1978: 239–52
16.
WhicherJTPerryDEHobbsJR. An evaluation of the Hyland laser nephelometer PDQ system for the measurement of immunoglobulins. Ann Clin Biochem1978; 15: 77–85
17.
SternbergCJ. A rate nephelometer for measuring specific proteins by immunoprecipitin reactions. Clin Chem1977; 23: 1456–64
18.
MalkusHBuschbaumPCastroA. An automated turbidimetric rate method for immunoglobulin assays. Clin Chim Acta1978; 88: 523–30
19.
FinleyPRWilliamsRJByersJM. Immunochemical determination of human immunoglobulins with a centrifugal analyser. Clin Chem1976; 22: 1037–41
20.
PriceCPSpencerKWhicherJ. Light-scattering immunoassay of specific proteins: A review. Ann Clin Biochem1983; 20: 1–14
21.
BryantDHBurnsMWLazarusL. The measurement of IgE in asthma by a new radioimmunoassay. Med J Aust1973; 2: 71–3
RadlJSepersJMSkarvilF. Immunoglobulin patterns in humans over 95 years of age. Clin Exp Immunol1975; 22: 84–90
24.
BockhautBA. Divergent results in radial immunodiffusion with antisera differing in precipitation properties with respect to individual immunoglobulin subclasses. II The antiserum factor. J Immunol Methods1975; 7: 199–210
25.
GillilandBC. Immunologic quantitation of serum immunoglobulins. Am J Clin Pathol1977; 68: 664–70
26.
Khayam-BashiHSlaughterSBlankenRM. Quantitative estimation of secretory immunoglobulin A by radial immunodiffusion technique. Clin Chim Acta1976; 66: 63–7
27.
HobbsJR. Immunoglobulins in clinical chemistry. Advances in Clinical Chemistry1971; 14: 219–317
28.
ThompsonEJ. Immunochemistry of CSF proteins. In: WardMilford AWhicherJT, eds. Immunochemistry in Clinical Laboratory Medicine. Lancaster UK: MTP Press, 1979; 229–36
29.
VirellaGFudenbergHH. Comparison of immunoglobulin determinations in pathological sera by radial immunodiffusion and laser nephelometry. Clin Chem1977; 23: 1925–8
30.
KillingsworthLMSavoryJ. Nephelometric studies of the precipitin reaction: A model system for specific protein measurement. Clin Chem1973; 19: 403–7
31.
ShenkinAMorrisonBRobertsonDA. Some problems in the correction for intrinsic light scattering of samples in specific protein analysis by automated immunoprecipitation. Ann Clin Biochem1977; 14: 163–70
32.
SmithAMThompsonRA. Paraprotein estimation: A comparison of immunochemical and densitometric techniques. J Clin Path1978; 31: 1156–60
33.
RitchieRFRippeyJH. Performance on immunoglobulin IgG, IgA and IgM tests in CAP survey specimens. Am J Clin Pathol1982; Suppl. 78: 644–50
34.
HellsingKEnstromH. Pre-treatment of serum samples for immunonephelometric analysis by precipitation with polyethylene glycol. Scand J Clin Lab Invest1977; 37: 529–36
35.
RoweDSAndersonSGGrabB. A research standard for human serum immunoglobulins IgG, IgA and IgM. Bull Wld Hlth Org1970; 42: 535–52
36.
RoweDSGrabBAndersonSG. An international reference preparation for human serum immunoglobulins G, A and M; content of immunoglobulins by weight. Bull Wld Hlth Org1972; 46: 67–79
37.
RoweDSAndersonSGTackettL. A research standard for human serum immunoglobulin D. Bull Wld Hlth Org1970; 43: 607–9
38.
WHO ECBS Technical Report Series No. 658, 1981, 23: 21
39.
WhicherJTHuntJPerryDE. Method-specific variations in the calibration of a new immunoglobulin standard suitable for use in nephelometric techniques. Clin Chem1978; 24: 531–5
40.
ReimerCBSmithSJWellsTW. Collaborative calibration of the US national and the College of American Pathologists reference preparations for specific serum proteins. Amer J Clin Pathol1982; 77: 12–9
41.
TonksDB. Some faults with external and internal quality control programs. Clin Biochem1982; 15: 67–8