We report on a patient with bilateral cochlear implants (a Med-El Combi40 and a Med-El Combi40+), as well as considerable experience in scuba diving with both of his implants. After having been exposed to 68 and 89 dives, respectively, in depths of up to 43 m, both cochlear implants are in working order and the patient continues to receive excellent speech recognition scores with both cochlear implant systems. The presented data show that scuba diving after cochlear implantation is possible over a considerable number of dives without any major negative impact on the implants.
AllumJHGreisigerRStraubhaarSCarpenterMG. Auditory perception and speech identification in children with cochlear implants tested with the EARS protocol. Br J Audiol2000; 34:293–303.
2.
HamzaviJFranzPBaumgartnerWDGstoettnerW. Hearing performance in noise of cochlear implant patients versus severely-profoundly hearing-impaired patients with hearing aids. Audiology2001;40:26–31.
3.
KompisMVischerMWHäuslerR. Performance of compressed analogue (CA) and continuous interleaved sampling (CIS) coding strategies for cochlear implants in quiet and noise. Acta Otolaryngol (Stockh)1999;119:659–64.
4.
HelmsJMüllerJSchönF. Comparison of the TEMPO+ ear-level speech processor and the CIS PRO+ body-worn processor in adult MED-EL cochlear implant users. ORL J Otorhinolaryngol Relat Spec2001;63:31–40.
5.
KompisMJenkMVischerMWSeifertEHäuslerR. Intra- and intersubject comparison of cochlear implant systems using the Esprit and the Tempo+ behind-the-ear speech processor. Int J Audiol2002;41:555–62.
6.
BackousDDDunfordRGSegelPMuhlockerMCCarterPHampsonNB. Effects of hyperbaric exposure on the integrity of the internal components of commercially available cochlear implant systems. Otol Neurotol2002;23:463–7.
7.
VibertDHäuslerRKompisMVischerM. Vestibular function in patients with cochlear implantation. Acta Otolaryngol Suppl (Stockh)2001(suppl 545):29–34.
8.
MüllerJSchönFHelmsJ. Speech understanding in quiet and noise in bilateral users of the MED-EL COMBI 40/40+ cochlear implant system. Ear Hear2002;23:198–206.
9.
KompisMSennPVischerMHäuslerR. Schalllokalisation und Sprachverständnis nach bilateraler Cochlea-Implantation. Z Audiol Suppl2001(suppl 4):44–6.
10.
SennPVischerMKompisMHäuslerR. Resultate nach bilateraler Cochlea-Implantation. Schweiz Med Forum Suppl2002(suppl 6):73S–75S.
11.
FishmanKEShannonRVSlatteryWH. Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor. J Speech Lang Hear Res1997; 40:1201–15.
12.
BrillSMGstöttnerWHelmsJ. Optimization of channel number and stimulation rate for the fast continuous interleaved sampling strategy in the COMBI 40+. Am J Otol1997; 18(suppl 6):S104–S106.