Rate of heat release and ignitability indices are applied to predict the European fire classification based on FIGRA values from Single Burning Item (SBI) tests for building products. Both indices can be calculated from cone calorimeter test results measured at 50 kW/m2. Within its validated range, the predictive procedure gives the correct classification for 90% of the products studied. The model provides a practical tool to support product development and quality control.
Babrauskas, V.1984. “Bench-scale methods for prediction of full-scale fire behaviour of furnishings and wall linings.” SFPE Technology Report 84-10. Boston, MA: Society of Fire Protection Engineers, 25 p.
2.
ISO 5660-1:1993. Fire tests—Reaction to fire—Part 1: Rate of heat release from building products (Cone calorimeter method). Geneva: International Organization for Standardization, 31 p.
3.
Östman, B. A.-L. and Nussbaum, R. M. 1989. “Correlation between Small-Scale Rate of Heat Release and Full-Scale Room Flashover for Surface Linings,” in Fire Safety Science—Proceedings of the Second International Symposium, T. Wakamatsu, Y. Hasemi, A. Sekizawa, P. G. Seeger, P. J. Pagni and C. E. Grant, ed., New York: Hemisphere Publishing Corporation, pp. 823-832.
4.
Östman, B. A.-L. and Tsantaridis, L. D.1994. “Correlation between Cone Calorimeter Data and Time to Flashover in the Room Fire Test,”Fire and Materials, 18: 205-209.
5.
Delichatsios, M. A. and Saito, K.1991. “Upward Fire Spread: Key Flammability Properties, Similarity Solutions and Flammability Indices,” in Fire Safety Science—Proceedings of the Third International Symposium, G. Cox and B. Langford, ed., London: Elsevier Science Publishers Ltd, pp. 217-226.
6.
Shields, T. J., Silcock, G. W. and Murray, J. J.1994. “Evaluating Ignition Data Using the Flux Time Product,”Fire and Materials, 18: 243-254.
7.
Tewarson, A.1994. “Flammability Parameters of Materials: Ignition, Combustion, and Fire Propagation,”Journal of Fire Sciences, 12(4): 329-356.
8.
Kokkala, M. A, Thomas, P. H. and Karlsson, B.1993. “Rate of Heat Release and Ignitability Indices for Surface Linings,”Fire and Materials, 17: 209-216.
9.
ISO 9705:1993. Fire tests—Full-scale room test for surface products. Geneva: International Organization for Standardization, 31 p.
10.
Final Draft prEN 13823. Reaction to fire tests for building products—Building products excluding floorings exposed to the thermal attack by a single burning item. Brussels: European Committee for Standardization, September 2000, 103 p.
11.
Messerschmidt, B., Van Hees, P. and Wickström, U. 1999. “Prediction of SBI (Single Burning Item) test results by means of cone calorimeter test results,” in Conference Proceedings of the 8th International Interflam Conference, London: Interscience Communications Ltd, pp. 11-22.
12.
Hakkarainen, T. and Kokkala, M. A.2001. “Application of a one-dimensional thermal flame spread model on predicting the rate of heat release in the SBI test,”Fire and Materials, 25: 61-70.
13.
“Commission Decision of 8 February 2000 Implementing Council Directive 89/106/EEC as regards the classification of the reaction to fire performance of construction products,”Official Journal of the European Communities No L 50, 23.2.2000, pp. 14-18.
14.
“Summary of principles leading to the SBI classification system (prepared by Official Laboratories Group).” Document RG N138, 1998. Brussels: European Commission, Directorate-General III, 21 p. (unpublished).
15.
Kokkala, M., Baroudi, D. and Parker, W. J. 1997. “Upward Flame Spread on Wooden Surface Products: Experiments and Numerical Modelling,” in Fire Safety Science—Proceedings of the Fifth International Symposium, Y. Hasemi, ed., International Association for Fire Safety Science, pp. 309-320.
16.
Tsantaridis, L. and Östman, B.1999. “Cone Calorimeter Data and Comparisons for the SBI RR Products.” Trätek Rapport I 9812090. Stockholm: Trätek, 46 p.
17.
Sundström, B., van Hees, P. and Thureson, P.1998. “Results and Analysis from Fire Tests of Building Products in ISO 9705, the Room/Corner Test.” SP Report 1998:11. Borås: Swedish National Testing and Research Institute, 33 p. + app. 36 p.
18.
Personal communication with Dr Jukka Hietaniemi of VTT.
19.
“FIGRA(SBI): analysis of accuracy and stability of classification.” Document OLG N44, 1998. Brussels: European Commission, Directorate-General III, 7 p. (unpublished).