LassenHCA. A preliminary report on the 1952 epidemic of poliomyelitis in Copenhagen with special reference to the treatment of acute respiratory insufficiency. Lancet, 1953; 261(6749):37-41.
2.
MarshallJ, SpaldingJMK. Humidification in positive-pressure respiration for bulbospinal paralysis. Lancet, 1953; 262(6794):1022-1024.
KapadiaF, ShellyMP, AnthonyJM, ParkGR. An active heat and moisture exchanger. Brit J Anaesth, 1992; 69(6):640-642.
5.
LelloucheF, QaderS, TailléS, LyazidiA, BrochardL. Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers. Respir Care, 2014; 59(5):637-643.
6.
International Organization for Standardization. Anaesthetic and respiratory equipment–heat and moisture exchangers (HMEs) for humidifying respired gases in humans–part 1: HMEs for use with minimum tidal volumes of 250 ml (ISO 9360-1:2000). Geneva: International Organization for Standardization; 2000.
7.
International Organization for Standardization. Respiratory tract humidifiers for medical use–particular requirements for respiratory humidification systems (ISO 8185:2007). Geneva: International Organization for Standardization; 2007.
8.
International Organization for Standardization. Anaesthetic and respiratory equipment—heat and moisture exchangers for use in humidifying respired gases in humans (ISO 9360:1992). Geneva: International Organization for Standardization; 1992.
9.
EckerbomB, LindholmCE. Performance evaluation of six heat and moisture exchangers according to the Draft International Standard (ISO/DIS 9360). Acta Anaesthesiol Scand, 1990; 34(5):404-409.
10.
BransonRD, DavisKJr. Evaluation of 21 passive humidifiers according to the ISO 9360 standard: moisture output, dead space and flow resistance. Respir Care, 1996; 41(8):736-743.
11.
MartinC, PapazianL, PerrinG, BantzP, GouinF. Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation > 10 L/min. Chest, 1992; 102(5):1347-1350.
12.
MartinC, ThomachotL, QuinioB, ViviandX, AlbaneseJ. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min. Chest, 1995; 107(5):1411-1415.
ChamneyAR. Humidification requirements and techniques. Including a review of the performance of equipment in current use. Anaesthesia, 1969; 24(4):602-617.
15.
WilkesAR. Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 1–history, principles and efficiency. Anaesthesia, 2011; 66(1):31-39.
16.
International Organization for Standardization. Humidifiers for medical use–safety requirements (ISO 8185:1988). Geneva: International Organization for Standardization; 1988.
17.
BransonRD, HurstJM. Laboratory evaluation of moisture output of seven airway heat and moisture exchangers. Respir Care, 1987; 32(9):741-747.
18.
LelloucheF, TailléS, MaggioreSM, QaderS, L'HerE, DeyeN, BrochardL. Influence of ambient air and ventilator output temperature on performances of heated-wire humidifiers. Am J Respir Crit Care Med, 2004; 170(10):1073-1079.