MazelaJ, PolinRA. Aerosol delivery to ventilated newborn infants: historical challenges and new directions. Eur J Pediatr, 2011; 170(4):433-444.
2.
FokTF, MonkmanS, DolovichM, GrayS, CoatesG, PaesB, et al. Efficiency of aerosol medication delivery from a metered dose inhaler versus jet nebulizer in infants with bronchopulmonary dysplasia. Pediatr Pulmonol, 1996; 21(5):301-309.
3.
ColeCH. Special problems in aerosol delivery: neonatal and pediatric considerations. Respir Care, 2000; 45(6):646-651.
4.
GriggJ, ArnonS, JonesT, ClarkeA, SilvermanM. Delivery of therapeutic aerosols to intubated babies. Arch Dis Child, 1992, 67(1 Spec No):25-30.
5.
EverardML. Ethical aspects of using radiolabeling in aerosol research. Arch Dis Child, 2003; 88(8):659-661.
6.
BallardJ, LugoRA, SalyerJW. A survey of albuterol administration practices in intubated patients in the neonatal intensive care unit. Respir Care, 2002; 47(1):31-38.
7.
ShahSS, OhlssonA, HallidayHL, ShahVS. Inhaled versus systemic corticosteroids for the treatment of chronic lung disease in ventilated very low birth weight preterm infants. Cochrane Database Syst Rev, 2007;(4):CD002057.
8.
NgG, da SilvaO, OhlssonA. Bronchodilators for the prevention and treatment of chronic lung disease in preterm infants. Cochrane Database Syst Rev, 2012;(6):CD003214.
9.
BrionLP, PrimhakRA, YongW. Aerosolized diuretics for preterm infants with (or developing) chronic lung disease. Cochrane Database Syst Rev, 2006;(3):CD001694.
10.
DunnMS, KaempfJ, de KlerkA, de KlerkR, ReillyM, HowardD, et al. ; Vermont Oxford Netwrok DRM Study Group. Randomized trial comparing 3 approaches to the initial respiratory management of preterm neonates. Pediatrics, 2011; 128(5):e1069-e1076.
11.
MorleyC, DavisPG, DoyleLW, BrionLP, HascoetJM, CarlinJB; COIN Trial Investigators. Nasal CPAP or intubation at birth for very preterm infants. N Engl J Med, 2008; 358(14):700-708.
12.
SUPPORT Study Group of the Eunice Kennedy Shriver NICHD Neonatal Research Network. Early CPAP versus Surfactant in extremely preterm infants. N Engl J Med, 2010; 362(21):1970-1979.
13.
AveryME, TooleyWH, KellerJB, HurdSS, BryanMH, CottonRB, et al. Is chronic lung disease in low birth weight infants preventable? A survey of eight centers. Pediatrics, 1987; 79(1):26-30.
14.
HoekstraRE, FerraraTB, CouserRJ, PayneNR, ConnettJE. Survival and long-term neurodevelopmental outcome of extremely premature infants born at 23-26 weeks' gestational age at a tertiary center. Pediatrics, 2004; 113(1):e1-e6.
Van MarterLJ. Epidemiology of bronchopulmonary dysplasia. Semin Fetal Neonatal Med, 2009; 14(6):358-366.
17.
SweetDG, CarnielliV, GreisenG, HallmanM, OzekE, PlavkaR, et al. European consensus guidelines on the management of neonatal respiratory distress syndrome in preterm infants - 2013 update. Neonatology, 2013; 103():353-368.
18.
BasslerD, PoetsCF. Efficacy and safety of inhaled budesonide in very preterm infants at risk for bronchopulmonary dysplasia (NEuroSIS). http://clinicaltrials.gov/show/NCT01035190. 2009. Accessed Jan 6, 2014.
19.
FarneyKD, KuehneBT, GibsonLA, NelinLD, ShepherdEG. In vitro evaluation of radio-labeled aerosol delivery via a variable-flow infant CPAP system. Respir Care, 2013; 59(3):340-344.
20.
AriA, AtalayOT, HarwoodR, SheardMM, AljamhanEA, FinkJB. Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation. Respir Care, 2010; 55(7):845-851.
21.
DaiB, KangJ, SunLF, TanW, ZhaoHW. Influence of exhalation valve and nebulizer position on albuterol delivery during noninvasive positive pressure ventilation. J Aerosol Med Pulm Drug Deliv, 2013 [E-pub ahead of print].
22.
CourtneySE, PyonKH, SaslowJG, ArnoldGK, PanditPB, HabibRH. Lung recruitment and breathing pattern during variable versus continuous flow nasal continuous positive airway pressure in premature infants: an evaluation of three devices. Pediatrics, 2001; 107(2):304-308.
23.
LongestPW, GolshahiL, HindleM. Improving pharmaceutical aerosol delivery during noninvasive ventilation: effects of streamlined components. Ann Biomed Eng, 2013; 41(6):1217-1232.