Abstract
BACKGROUND:
Gait speed is a simple physical function measure associated with key outcomes in the elderly population. Gait speed measurements may improve clinical care in patients with COPD. However, there is a knowledge gap about the reliability and variability of gait speed testing protocols in COPD. We evaluated established techniques of measuring gait speed in patients with COPD and assessed feasibility of implementing gait speed as a routine
METHODS:
The
RESULTS:
Seventy subjects enrolled; 60% were men, and the mean age ± SD was 69 ± 10 years. All methods showed excellent test-retest reliability (intraclass correlation coefficient of 0.95–0.97). The difference between the two timing systems did not exceed the suggested minimal clinically important difference of 0.1 m/s for the usual pace instructions but did exceed 0.1 m/s for maximal pace walks. The difference between 4MGS and 10MGS was 0.13 ± 0.10 m/s.
FEASIBILITY:
Most subjects reported that gait speed measurement prior to clinic appointment was very acceptable (66%) or acceptable (33%). Time added to clinic visit measuring 4MGS was 95 ± 20 seconds, and clinical assistants reported gait speed measurements as very acceptable (60%), acceptable (30%), and somewhat acceptable (10%).
CONCLUSIONS:
Gait speed is a reliable measure in COPD, regardless of instructed pace, distance, or timing mechanism; however, adhering to one protocol is suggested. 4MGS was easily implemented into clinical practice with high acceptability by patients and clinic staff.
Keywords