Abstract
OBJECTIVE:
To retrospectively explore correlation of the resected specimen volume of breast microcalcification lesions and endogenous and exogenous factors of stereotactic needle localization biopsy (SNLB).
MATERIALS AND METHODS:
Totally 214 patients underwent SNLB for non-palpable breast lesion with microcalcification lesions. Of 211 patients, 198 patients underwent single needle localization and 13 patients underwent multi-needle localization (26 lesions). Lesion sizes, distribution characteristics, lesion localization accuracy and resected specimen volumes were recorded and analyzed using a generalized linear model (GLM).
RESULTS:
The average lesion diameter is 2.63±1.73 cm. The localization accuracy of 187 lesions were moderate, 26 were too deep and 11 were too superficial. The mean resected specimen volume (V) was 17.51±5.14 cm3. One-way ANOVA analysis showed that 3 factors, including lesion sizes, distribution characteristics and the localization accuracy were associated with resected specimen volume (F = 67.56–112.78,
CONCLUSION:
Average lesion diameter and localization accuracy are highly significant variables for the resected specimen volume. Localization accuracy as a subjective controllable variable is one of the important factors that determine the volume of lesion resection. Single clustered distribution was more susceptible localization accuracy than other characteristic distributions. Improving localization accuracy can reduce resected specimen volume, which can reduce breast defect to a certain extent.
Keywords
Get full access to this article